检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张材 王慧文 Zhang Cai;Wang Huiwen(Shanxi Taigang Stainless Steel Precision Strip Co.,Ltd.,Taiyuan 030006,Shanxi,China)
机构地区:[1]山西太钢不锈钢精密带钢有限公司,山西太原030006
出 处:《云南化工》2023年第11期163-165,共3页Yunnan Chemical Technology
摘 要:介绍了除盐水双级反渗透系统工艺,分析了影响双级反渗透装置除盐水电导率与产水量的主要因素,提出了通过控制进水的污染指数SDI,进水余氯、进水温度、反渗透系统运行压力、反渗透膜的污染状况、回收率等参数提高除盐水质量与产量的对策。对反渗透装置运行过程中存在的主要问题反渗透膜污染等做初步分析探讨,提出了控制与处置措施。The process of a two-stage reverse osmosis system for desalinated water was introduced,and the main factors affecting the conductivity and water yield of the desalinated water in the two-stage reverse osmosis device were analyzed.Measures were proposed to improve the quality and production of desalinated water by controlling the pollution index SDI of the inlet water,residual chlorine in the inlet water,inlet temperature,operating pressure of the reverse osmosis system,pollution status of the reverse osmosis membrane,recovery rate,and other parameters.Preliminary analysis and discussion were conducted on the main problems such as reverse osmosis membrane fouling during the operation of reverse osmosis devices,and control and disposal measures were proposed.
关 键 词:反渗透装置 SDI 电导率 反渗透膜污染 膜清洗 盐透过率
分 类 号:X784[环境科学与工程—环境工程]