ZD-6型电动转辙机“接点反弹”的故障分析及预防  被引量:3

Fault Analysis and Prevention of"Contact Rebound"of ZD-6 Electric Switch Machine

在线阅读下载全文

作  者:胡婕 徐锦材 郭予广 Hu Jie;Xu Jincai;Guo Yuguang(Guangzhou Metro Group Co.,Ltd.,Guangzhou 510330,China)

机构地区:[1]广州地铁集团有限公司,广州510330

出  处:《铁路通信信号工程技术》2023年第11期106-111,共6页Railway Signalling & Communication Engineering

摘  要:地铁线网的不断拓展,正线及车辆段对ZD-6型电动转辙机使用要求越来越高。针对ZD-6型电动转辙机摩擦联结器的结构特点,分析现场转辙机运作时出现“接点反弹”现象及摩擦电流不达标的问题原因,提出一些日常维护处理方法。With the continuous expansion of the subway network,the main line and depot have higher and higher requirements for the use of ZD-6 electric switch machine.In view of the structural characteristics of the friction coupling of ZD-6 electric switch machine,this paper analyzes the causes of the"contact rebound"phenomenon and the problem that the friction current does not up to standard during the operation of the on-site switch machine,and puts forward some daily maintenance methods.

关 键 词:电动转辙机 摩擦联结器 接点反弹 摩擦电流 

分 类 号:U284.7[交通运输工程—交通信息工程及控制]

 