一种动态温场的校准方法及其不确定度评定  

A calibration method for dynamic temperature field and its uncertainty evaluation

在线阅读下载全文

作  者:钟一峰 牛亚琳 朱晨彬[1] Zhong Yifeng;NiuYalin;Zhu Chenbin(Shanghai Institute of Measurement and Testing Technology)

机构地区:[1]上海市计量测试技术研究院

出  处:《上海计量测试》2023年第5期2-4,共3页Shanghai Measurement and Testing

基  金:上海市市场监督管理局科技计划项目(2022-21)。

摘  要:通过分析现有标准方法中因忽略温度传感器的动态特性所引入的误差,提出了一种动态温场的校准方法。该方法考虑了温度传感器的动态特性对动态温场校准结果的影响,使用连续记录温度曲线的方式代替现有较长记录间隔的数据记录方式对温场的动态性能进行测试,并结合不确定度分析的手段,给出被测动态温场校准结果。In this paper,a calibration method for dynamic temperature field is proposed by analyzing the error introduced by ignoring the dynamic characteristics of temperature sensors in existing standard methods.This method considers the influence of the dynamic characteristics of the temperature sensor on the dynamic temperature field calibration results,uses the continuous recording of the temperature curve instead of the existing data recording method with a long recording interval to test the dynamic performance of the temperature field,and combines the uncertainty analysis to give the confidence interval of the measured dynamic temperature field calibration results.

关 键 词:动态温场 热响应时间 不确定度分析 

分 类 号:TB942[一般工业技术—计量学]

 