基于火焰离子电流自适应检测的研究及探讨  

Research and Discussion on Adaptive Detection Based on Flame Ion Current

在线阅读下载全文

作  者:曹红风 

机构地区:[1]广东万和热能科技有限公司,佛山528305

出  处:《日用电器》2023年第10期77-80,共4页ELECTRICAL APPLIANCES

摘  要:本文针对火焰离子电流检测模块长时间使用以及根据设备的使用环境状况变化而引起的误判进行研究。对检测离子流火焰信号的交流信号参数进行调整,使交流信号根据设定值要求进行调整变化,对应不同的设备的环境变化及设备要求不同的变化,使对应的条件而进行变化,使用相同的火焰电流值就可以检测到火焰。按PID方式对设定适应检测离子电流的值,可以提高火焰检测效率及减少误判,根据设备不同对设定值进自动适应调整。In this paper,the misjudgment caused by the long-term use of flame ion current detection module and the change of equipment operating environment is studied.The AC signal parameters of the detection of the ion current flame signal are adjusted,so that the AC signal is adjusted and changed according to the requirements of the set value,corresponding to the environmental changes of different equipment and different changes in equipment requirements,so that the corresponding conditions are changed,and the flame can be detected by using the same flame current value.PID setting can improve the flame detection efficiency and reduce misjudgment,and automatically adjust the set value according to different equipment.

关 键 词:火焰信号 自适应 燃气具 

分 类 号:TM933.1[电气工程—电力电子与电力传动]

 