作 者:李光明 段毅宏[2] LI Guang-ming;DUAN Yi-hong(Department of Laboratory,Xishuangbanna Dai Autonomous Prefecture Center for Disease Control and Prevention,Jinghong,Yunnan 666100,China;不详)
机构地区:[1]西双版纳傣族自治州疾病预防控制中心卫生检验科,云南景洪666100 [2]云南省疾病预防控制中心卫生检验中心
出 处:《中国卫生检验杂志》2023年第20期2460-2465,共6页Chinese Journal of Health Laboratory Technology
摘 要:目的建立一种利用固相萃取结合气相色谱-质谱法(GC-MS)同时检测饮用水中18种多氯联苯(polychlorinated biphenyls,PCBs)和16种多环芳烃(Polycyclic Aromatic Hydrocarbons,PAHs)残留的分析方法。方法水样加入5‰体积甲醇改良极性,使用固相萃取法提取,无水硫酸钠脱水,经旋转蒸发仪浓缩,采用TG-1701MS毛细管色谱柱,GC-MS进行分析,用外标法定量。结果在0.5μg/L~200.0μg/L的浓度范围内18种多氯联苯(PCBs)和16种多环芳烃(PAHs)能够有效分离、峰形较好,标准曲线线性关系良好,方法线性相关系数r>0.999,方法检出限为0.05 ng/L~3 ng/L,回收率为77.5%~124.5%,相对标准偏差(RSD)为0.84%~2.98%。结论该方法简便、快速、整体成本较低、实用性强,检测指标广,回收率和检出限均能满足样品分析质量控制要求,适合饮用水中多氯联苯(PCBs)和多环芳烃(PAHs)的同时检测分析。Objective This paper aims to establish a method for the simultaneous detection of 18 polychlorinated biphenyls(PCBs)and 16 polycyclic aromatic hydrocarbons(PAHs)residues in drinking water by solid-phase extraction combined with gas chromatography-mass spectrometry(GC-MS).Methods The water samples were added with 5‰volume of methanol to improve the polarity.They are extracted by solid phase extraction,dehydrated with anhydrous sodium sulfate,and concentrated by rotary evaporator.TG-1701MS capillary column and GC-MS were adopted for analysis,and external standard method was used for quantification.Results The 18 polychlorinated biphenyls(PCBs)and 16 polycyclic aromatic hydrocarbons(PAHs)could be effectively separated in the concentration range of 0.5μg/L-200.0μg/L and showed good peak shape.The linearity of the standard curve was good.The linear correlation coefficient(r)of the method was more than 0.999.The detection limit of the method was within 0.05 ng/L-3 ng/L.The recoveries were within 77.5-124.5%.The relative standard deviations(RSDs)were within 0.84%-2.98%.Conclusion The method is convenient,rapid,practical and characterized by low cost and wide detection index.Recovery and detection limit meet the quality control requirements of sample analysis.It is suitable for the simultaneous detection and analysis of polychlorinated biphenyls(PCBs)and polycyclic aromatic hydrocarbons(PAHs)in drinking water.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28