作 者:李铁成 范辉 臧谦 任江波 张卫明 王义波 LI Tiecheng;FAN Hui;ZANG Qian;REN Jiangbo;ZHANG Weiming;WANG Yibo(State Grid Hebei Electric Power Research Institute,Shijiazhuang 050021,China;State Grid Hebei Electric Power Co.,Ltd.,Shijiazhuang 050021,China;Wuhan Kemov Electric Co.,Ltd.,Wuhan 430223,China)
机构地区:[1]国网河北省电力有限公司电力科学研究院,河北石家庄050021 [2]国网河北省电力有限公司,河北石家庄050021 [3]武汉凯默电气有限公司,湖北武汉430223
出 处:《中国电力》2023年第11期113-120,共8页Electric Power
基 金:国家自然科学基金资助项目(51877084);国网河北省电力有限公司科技项目(KJ2022-001)。
摘 要:基于遥信数据的线性区段定位方法没有考虑通信时延和可靠性的影响,且仅适用于大电流故障和单重故障,对此,提出一种基于5G通信的有源配电网多点同步保护方案。首先,建立基于5G通信的区段定位通信架构,并分析其通信时延和可靠性;其次,在分析暂态零序电流方向分布特点的基础上,对开关函数重新进行定义,提出一种适用于小电流故障的逻辑关系定位模型;然后,采用左右逼近方法,将根据逻辑关系建立的开关函数线性化,最终使得线性化后的逻辑关系定位模型不仅适用于单重故障,而且适用于多重故障;最后,基于不同拓扑结构和5G通信的有源配电网算例对所提保护方案进行了验证,结果表明所提方案不仅能够实现多点同步保护,而且适用于小电流故障和多重故障。The linear section location method based on remote signaling data does not consider the influence of communication timedelay and reliability,and is only applicable to large current faults and single faults.In this regard,a multi-point synchronous protection scheme for active distribution network based on 5G communication is proposed.Firstly,a section location communication architecture based on 5G communication is established,and its communication time-delay and reliability are analyzed.Secondly,on the basis of analyzing the direction distribution characteristics of the transient zero-sequence current,the switching function is redefined,and a logical relationship location model suitable for small current faults is proposed.Then,using the left-right approximation method,the switching function established according to the logic relationship is linearized,which makes the linearized logic relationship location model not only suitable for single faults,but also for multiple faults.Finally,the proposed protection scheme is validated in an active distribution network with different topologies and 5G communication.The results show that the proposed scheme can not only realize multi-point synchronous protection,but also be applicable to both small current faults and multiple faults.
关 键 词:有源配电网 同步保护 5G通信 小电流故障 多重故障 暂态零序电流
分 类 号:TN929.5[电子电信—通信与信息系统] TM77[电子电信—信息与通信工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.148.247.210