检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杜慧勇 尤子豪 李可 李民 杨自冬 任思铭 DU Huiyong;YOU Zihao;LI Ke;LI Min;YANG Zidong;REN Siming(College of Vehicle and Traffic Engineering,Henan University of Science and Technology,Luoyang 471003,China;Gu An Denox Environmental Protection Equipment Manufacturing Co.,Ltd.,Langfang 065500,China)
机构地区:[1]河南科技大学车辆与交通工程学院,河南洛阳471003 [2]固安迪诺斯环保设备制造有限公司,河北廊坊065000
出 处:《河南科技大学学报(自然科学版)》2024年第1期27-34,M0004,共9页Journal of Henan University of Science And Technology:Natural Science
基 金:国家重点研发计划项目(2016YFD0700700)。
摘 要:为了改善柴油机低排温(200℃)下尿素雾化效果不好的问题,本文研究了柴油机低排温条件下混合器本体温度对SCR系统的影响。基于云内4102柴油机,在1200 r·min^(-1)、20%负荷条件下,运用计算流体动力学(CFD)技术进行数值模拟。通过对比2种混合器的压降、迹线、混合器上壁面液膜分布情况,选取更适合的混合器类型。通过改变混合器的本体温度,来对比分析不同温度的混合器对壁面液膜和催化器前端NH 3均匀性系数的影响。研究结果表明:混合器本体温度的变化对于液膜的形成影响较大,混合器本体温度从100℃升高到200℃时,混合器上液膜区域明显减少。混合器本体温度的升高对NH 3均匀性系数有显著影响。随着混合器本体温度升高,NH 3均匀性系数明显升高,且随着温度的不断升高,NH 3均匀性系数越来越接近1。使混合器保持合适的温度,能够有效提高尿素的雾化效果和NH 3均匀性系数。In order to improve the poor urea atomization effect of diesel engine at low exhaust temperature(200℃),this paper studied the influence of mixer body temperature on SCR system under low exhaust temperature condition of diesel engine.Based on 1200 r·min^(-1),20%load condition of 4102 diesel engine in the cloud,CFD(computational fluid dynamics)technology was used for numerical simulation.By comparing the pressure drop,trace,and liquid film distribution on the upper wall of the two mixers,the more suitable mixer type was selected.By changing the temperature of the mixer,the influence of different temperature of the mixer on the wall liquid film and the NH 3 uniformity coefficient in front of the catalytic converter was compared and analyzed.The results show that the temperature change of the mixer body has a great influence on the formation of liquid film.When the temperature of the mixer increases from 100℃to 200℃,the liquid film area on the mixer decreases obviously.The increase of the body temperature of the mixer has a significant effect on the NH 3 uniformity coefficient.As the temperature of the mixer body increases,the uniformity coefficient of NH 3 increases obviously,and the uniformity coefficient of NH3 is closer and closer to 1 with the increasing temperature.The results show that the atomization effect of urea and the uniformity coefficient of NH 3 can be effectively improved by keeping the mixer at a proper temperature.
关 键 词:柴油机 CFD 混合器本体温度 液膜 NH 3均匀性系数
分 类 号:TK421.5[动力工程及工程热物理—动力机械及工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.133.107.82