检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张瑜 彭思琦 陈昀昊 张净 ZHANG Yu;PENG Si-qi;CHEN Yun-hao;ZHANG Jing(China Mobile Group Design Institute Co.,Ltd.,Beijing 100080,China)
机构地区:[1]中国移动通信集团设计院有限公司,北京100080
出 处:《电信工程技术与标准化》2023年第S01期60-63,共4页Telecom Engineering Technics and Standardization
摘 要:基于某省峰谷电价政策,本文提出3种针对站点的错峰用电方案及相应方案所需的磷酸铁锂电池扩充容量计算方法。以典型汇聚机房为例,对3种错峰用电方案的综合经济效益进行计算、对比和分析,为全网错峰用电的实施及后续新建站点的配置提供参考与帮助。Based on the peak-valley electricity price policy of some province,three staggering power electricity consumption strategies for existing sites are proposed.The calculation method of lithium iron phosphate battery expansion capacity required by the corresponding strategies are also presented.Taking a typical convergence server room as an example,the comprehensive economic benefits of the three schemes are calculated,compared and analyzed to provide reference and help for the implementation of staggering power consumption in the whole network and the configuration of the newly built sites in the future.
分 类 号:TN86[电子电信—信息与通信工程]