螺旋断层放射治疗(TOMO)机房辐射屏蔽分析  被引量:1

Analysis of Radiation Shielding in Spiral Tomography Radiotherapy(TOMO)Room

在线阅读下载全文

作  者:赵红 陶由之 Zhao Hong;Tao Youzhi(Sichuan Nuclear Industry Radiation Testing and Protection Institute(Sichuan Nuclear Emergency Technical Support Center),Chengdu,Sichuan 610052)

机构地区:[1]四川省核工业辐射测试防护院(四川省核应急技术支持中心),四川成都610052

出  处:《现代工程科技》2023年第19期67-70,共4页Modern Engineering Technology

摘  要:为了验证螺旋断层放射治疗(TOMO)机房的辐射防护设计方案的可靠性,根据相关规范计算螺旋断层放射治疗(TOMO)机房屏蔽体的理论计算结果,将辐射防护方案TOMO机房各侧屏蔽体设计厚度和机房屏蔽体的理论计算厚度进行比较。结果表明,运用该规范核算螺旋断层放射治疗(TOMO)机房各屏蔽体厚度的结果是可靠的,取值是合理的,机房屏蔽体理论计算厚度小于机房屏蔽体设计厚度,辐射防护设计方案的屏蔽效果满足国家现行标准的要求。In order to verify the reliability of the radiation protection design scheme for the spiral tomotherapy(TOMO)machineroom,calculates the theoretical calculation results of the shielding body of the TOMO machine room according to relevant specifications,and compares the design thickness of the shielding body on each side of the TOMO machine room with the theoretical calculation thickness of the shielding body of the machine room.The results indicate that the calculation of the thickness of each shielding body in the spiral tomotherapy(TOMO)room using this specification is reliable and the values are reasonable.The theoretical calculated thickness of the shielding body in the room is less than the design thickness of the shielding body in the room,and the shielding effect of the radiation protection design scheme meets the requirements of current national standards.

关 键 词:TOMO 屏蔽计算 辐射防护 环境保护 

分 类 号:R144[医药卫生—公共卫生与预防医学]

 