检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李昊泽 王利 闫雪松 Li Haoze;Wang Li;Yan Xuesong(Chifeng Yunnan Cloud Copper Metal Co.,Ltd,Inner Mongolia Chifeng 024000,China)
机构地区:[1]赤峰云铜有色金属有限公司,内蒙古赤峰024000
出 处:《实验与分析》2023年第2期53-55,共3页LABOR PRAXIS
摘 要:为建立碱熔酸浸-电感耦合等离子体原子发射光谱法测定铅冶炼锡渣中锡的检测方法,选择过氧化钠在高温炉内700℃溶解样品,仪器波长谱线为189.991 nm,添加空白溶液去除共存元素干扰,该实验条件下,铅冶炼锡渣中锡测定结果相对标准偏差在0.31%~1.18%之间(n=5),样品加标回收率为96.4%~102%。该方法结果准确、检测周期短、适合批量检测,可满足快速检测的分析要求。To establish a method for the determination of tin in lead smelting tin slag by alkaline acid leaching inductively coupled plasma atomic emission spectrometry.Sodium peroxide was selected to dissolve the samples in a high temperature furnace at 700℃,the instrument wavelength spectral line was 189.991nm,and the blank solution was added to remove the interference of co-existing elements.Under this experimental condition,the relative standard deviation of the tin determination results in lead smelting tin slag was between 0.31%~1.18%(n=5),and the recovery rate of the sample was 96.4%~102%.The method has accurate results,short detection cycle,suitable for batch detection,and can meet the requirements of rapid detection analysis.
分 类 号:TF814[冶金工程—有色金属冶金]