严寒地区医院病房气流组织优化  被引量:1

Optimization of air distribution in hospital wards in severe cold area

在线阅读下载全文

作  者:张淑秘[1,2] 周冠丞 盛昱强 陆继凤 姜珊[1] 李春辉[1] 张喜明[1] 赵嵩颖[3] ZHANG Shumi;ZHOU Guancheng;SHENG Yuqiang;LU Jifeng;JIANG Shan;LI Chunhui;ZHANG Ximing;ZHAO Songying(College of Municipal and Environmental Engineering,Jilin Jianzhu University,Changchun 130118,China;Key Laboratory for Comprehensive Energy Saving of Cold Regions Architecture of Ministry of Education,Jilin Jianzhu University,Changchun 130118,China;Graduate Student Department,Jilin Jianzhu University,Changchun 130118,China)

机构地区:[1]吉林建筑大学市政与环境工程学院,吉林长春130118 [2]吉林建筑大学寒地建筑综合节能教育部重点实验室,吉林长春130118 [3]吉林建筑大学研究生处,吉林长春130118

出  处:《热科学与技术》2023年第5期489-497,共9页Journal of Thermal Science and Technology

基  金:吉林省科技发展计划资助项目(20230203115SF)。

摘  要:以严寒地区三家大型综合医院为研究对象,采用现场实测与CFD模拟相结合的研究手段,连续测试了各医院典型病房的温度、湿度、二氧化碳浓度以及细菌微生物的质量浓度。测试结果表明,不同的送排风口位置对污染物浓度影响较明显,其中采用侧送下回气流组织形式的病房受污染程度最低。并运用CFD对不同气流组织形式的流场进行模拟,验证了现场实测的结论,得出中央散流器送风病床区回风的气流组织形式可实现对病人呼出污染气体有效控制的结论。可明显降低医患间以及患患间交叉感染的概率,为医院病房气流组织优化提供理论依据。Three large general hospitals in severe cold areas are used as the research objects.Combining on-site measurement and CFD simulation,the temperature,humidity,carbon dioxide concentration and the mass concentration of bacteria and microorganisms in typical wards of each hospital are obtained.The testresults show thatthe position of the air supply and exhaust outlet has a significant impact on the concentration of pollutants.Among them,the ward with the side-feed and lower-return airflow organization is the least contaminated.The flow fields with different airflow organizations are simulated by CFD,which verifies the conclusion of the test.It is proposed that the airflow organization form of the return air in the side-supplied hospital bed area can effectively control the airborne pathogenic gas exhaled by the patient,reduce the probability of cross-infection between doctors and patients,and provide a theoretical basis for the optimization of airflow organization in hospital wards.

关 键 词:严寒地区 医院病房 现场实测 CFD模拟 气流组织 

分 类 号:TK529[动力工程及工程热物理—热能工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象