检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Chunwen Xu Yijing Ren Na Li Li Liu Xiong Mei Yanchao Fan
机构地区:[1]College of Pipeline and Civil Engineering,China University of Petroleum,Qingdao,266580,China [2]Department of Building Science,School of Architecture,Tsinghua University,Beijing,100084,China [3]School of Energy and Power Engineering,Changsha University of Science and Technology,Changsha,410114,China [4]East China Architectural Design and Research Institute,Shanghai,200002,China
出 处:《Building Simulation》2023年第11期2077-2092,共16页建筑模拟(英文)
基 金:This study was financially supported by the National Natural Science Foundation of China(52278131,551808555);the Natural Science Foundation of Shandong Province(ZR2019MEE060);the Opening Fund of State Key Laboratory of Green Building in Western China(LSKF202014);the Danish Agency for Higher Education and Science International Network Programme(case no.0192-00036B).
摘 要:The effectiveness of using personalized ventilation(PV)in mitigating airborne transmission risk was found to be easily affected by multiple factors.The aim of this study was hereby to evaluate the impacts of several important factors on the performance of PV in airborne disease control for closely ranged occupants.Orthogonal experiments were designed for CFD simulations under different levels of four selected factors.Results indicated that the order of significance of these four factors affecting the intake fraction(IF)of the exposed occupant was as follows:mode of PV use>relative distance between occupants>PV airflow volume>background ventilation.The best combination of the four tested factors was PV of 15 L/s for both the infected source and the exposed occupant,with a relative distance of 2 m between them and mixing ventilation,which would yield an IF of merely 0.0246%.The worst combination was PV of 6 L/s for the exposed occupant only,with a relative distance of 0.86 m under displacement ventilation,indicating an elevated IF of 0.2919%.The increase of PV air volume and relative separation distance both contributed to lower exposure risk,but they were not as influential as the mode of PV use.PV integrated with mixing ventilation and utilized for both infected and susceptible occupants were recommended.The findings in this study will be helpful to provide guidance for the implementation of PV in indoor environment for airborne infection control.
关 键 词:personalized ventilation intake fraction airborne transmission orthogonal experiment CFD simulation
分 类 号:TU83[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.43