BNS酸性管线管氢致开裂试验不合格原因分析  被引量:1

Analysis of HIC Test Failure of BNS Sour Linepipe

在线阅读下载全文

作  者:李端正 蒋炎 郑秋艳 LI Duanzheng;JIANG Yan;ZHENG Qiuyan(Hunan Hengyang Steel Pipe(Group)Co.,Ltd.,Hengyang 421001,China)

机构地区:[1]湖南衡阳钢管(集团)有限公司,湖南衡阳421001

出  处:《金属材料与冶金工程》2023年第6期13-19,共7页Metal Materials and Metallurgy Engineering

摘  要:通过对原材料理化、金相、能谱分析及氢致开裂(HIC)试样的相关分析来验证HIC试验不合格的原因。结果表明:原材料本身存在带状组织和变形的非金属夹杂物是HIC试验不合格的原因。带状组织具有较好的输氢通道,轧制后形成的高位错密度加速氢原子扩散;变形的A类非金属夹杂物周围应力集中,使氢原子更容易聚集形成局部富集。处于H2S环境下的试样在带状组织和变形的非金属夹杂物共同作用下,引起氢原子聚集,当富集区氢压超过材料抗拉强度时引起氢致开裂。Through mechanical and chemical analysis,metallographic analysis,energy spectrum analysis on raw material and analysis of hydrogen-induced cracking(HIC)specimens to verify the reason of HIC test failure.Analysis results show the reason for the failure is caused by the raw material with band structure and deformed non-metallic inclusions.Band structure has a good hydrogen transport channel.High density dislocations formed after rolling accelerate hydrogen atoms diffusion.The concentration of stress around deformed Class A nonmetallic inclusions makes it easier for hydrogen atoms aggregation and form local enrichment.When samples are exposed to H,S environment,band structure and deformed non-metallic inclusions cause hydrogen atoms aggregation.Hydrogen-induced cracking occurs when the hydrogen pressure in the enriched area exceeds the tensile strength of the material.

关 键 词:氢致开裂 带状组织:非金属夹杂物 H2S环境 

分 类 号:TG142.15[一般工业技术—材料科学与工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象