Low-cost spectrometer design for ultra-high resolution spectral domain optical coherence tomography  被引量:3

在线阅读下载全文

作  者:陈朝良 蒲郁蕊 史伟松 Chaoliang Chen;Yurui Pu;Weisong Shi(Advanced Photonics Center,School of Electronic Science&Engineering,Southeast University,Nanjing 210096,China;Department of Optical Engineering,Nanjing University of Science and Technology,Nanjing 210094,China)

机构地区:[1]Advanced Photonics Center,School of Electronic Science&Engineering,Southeast University,Nanjing 210096,China [2]Department of Optical Engineering,Nanjing University of Science and Technology,Nanjing 210094,China

出  处:《Chinese Optics Letters》2023年第10期19-23,共5页中国光学快报(英文版)

基  金:supported by the Natural Science Foundation of Jiangsu Province(No.BK20210227).

摘  要:In this Letter,we present a low-cost,high-resolution spectrometer design for ultra-high resolution optical coherence tomography(UHR-OCT),in which multiple standard achromatic lenses are combined to replace the expensive F-theta lens to achieve a comparable performance.For UHR-OCT,the spectrometer plays an important role in high-quality 3D image reconstruction.Typically,an F-theta lens is used in spectrometers as the Fourier lens to focus the dispersed light on the sensor array,and this F-theta lens is one of the most expensive components in spectrometers.The advantage of F-theta lens over the most widely used achromatic lens is that the aberrations(mainly spherical aberration,SA)are corrected,so the foci of the dispersed optical beams(at different wavelengths)with different incident angles could be placed on the sensor array simultaneously.For the achromatic lens,the foci of the center part of the spectrum are farther than those on the side in the longitudinal direction,causing degradations of the spectral resolution.Furthermore,in comparison with the achromatic lens with the same focal length,those with smaller diameters have stronger SA,but small lenses are what we need for making spectrometers compact and stable.In this work,we propose a simple method of using multiple long-focal-length achromatic lenses together to replace the F-theta lens,which is>8-fold cheaper based on the price of optical components from Thorlabs,US.Both simulations and in vivo experiments were implemented to demonstrate the performance of the proposed method.

关 键 词:low-cost spectrometer optical coherence tomography spherical aberration suppression ultrahigh-resolution non-invasive imaging 

分 类 号:TP391.41[自动化与计算机技术—计算机应用技术] O439[自动化与计算机技术—计算机科学与技术]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象