作 者:李程 LI Cheng
机构地区:[1]国网咸宁市咸安区供电公司,湖北咸宁437000
出 处:《电力系统装备》2023年第11期37-39,共3页Electric Power System Equipment
摘 要:在特高压架空输电线路中,由于张力放线在架设期间的整体性比较强,其中任何一个环节发生问题,都会影响整个施工工序,甚至造成安全风险。基于此,文章分析了特高压架空输电线路张力放线施工技术的意义,探究了特高压架空输电线路张力放线施工技术要点,并提出了施工保障措施,以期为相关人员提供参考。In ultra-high voltage overhead transmission lines,due to the strong integrity of tension stringing during installation,any problem in any link can affect the entire construction process and even cause safety risks.Based on this,the article first analyzes the significance of the tension stringing construction technology for ultra-high voltage overhead transmission lines,and then explores the key points of the tension stringing construction technology for ultra-high voltage overhead transmission lines,and proposes several construction guarantee measures to provide reference for relevant personnel.