检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:聂铭 和敬涵[1] 李猛 张慧媛 陈可傲 李艳 NIE Ming;HE Jinghan;LI Meng;ZHANG Huiyuan;CHEN Keao;LI Yan(School of Electrical Engineering,Beijing Jiaotong University,Beijing 100044,China;Economic and Electric Research Institute of State Grid Shanxi Electric Power Company,Taiyuan 030024,China)
机构地区:[1]北京交通大学电气工程学院,北京100044 [2]国网山西省电力公司经济技术研究院,山西太原030024
出 处:《电力系统保护与控制》2023年第24期33-43,共11页Power System Protection and Control
基 金:国家自然科学基金项目资助(52007003);国家电网有限公司科技项目资助(5200-202256081A-1-1-ZN)。
摘 要:柔性直流电网故障电流上升速度快与电力电子器件过流能力弱形成突出矛盾,线路保护需要在数毫秒级完成故障判别,输电线路精确参数的获取对于提升继电保护的性能至关重要。然而直流系统中缺乏稳定基频,导致输电线路相关参数难以获取、保护实现较为困难。针对柔性直流线路频变参数难以获取的问题,提出基于半桥模块化多电平换流器(half bridge modular multilevel converter, HB-MMC)特征信号注入的柔性直流线路频变参数辨识方法。首先通过换流器控制在线路中注入特定频率信号,然后利用快速傅里叶分解提取不同频率的信号并计算指定频率下的线路参数,最后依据不同线路参数的频变特性拟合出对应的幅频特性曲线。仿真表明,所提参数辨识方法可以准确拟合保护所需直流线路频变参数,参数辨识频段内相对误差小于1.5%。The rapid rise of fault current in a flexible DC grid has a prominent contradiction with the weak overcurrent capability of power electronics elements.The DC line protection needs to complete the fault identification in a few milliseconds.Accurate parameter identification of transmission lines is very important in improving the performance of relay protection.However,the lack of a stable fundamental frequency in the DC system makes it difficult to obtain the relevant parameters of the transmission line and to realize the protection principle.There is difficulty in obtaining the frequency-dependent parameters of flexible DC lines.Thus a flexible DC line parameter identification method based on characteristic signal injection with a half-bridge modular multilevel converter(HB-MMC)is presented.By changing the control strategy of the converter,a characteristic signal is injected into the transmission line.Then the signal of different frequencies is extracted by fast Fourier transform and the line parameters at the specified frequencies are calculated.Finally,the corresponding amplitude-frequency characteristic curves are fitted according to the frequency-dependent characteristics of different line parameters.The simulation results show that the proposed parameter identification method can accurately fit the DC transmission line frequency-dependent parameters,and the relative error of the whole parameter identification is less than 1.5%.This work is supported by the National Natural Science Foundation of China(No.52007003).
关 键 词:半桥模块化多电平换流器 特征信号注入 线路参数计算 频变参数
分 类 号:TM721.1[电气工程—电力系统及自动化] TM75
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.63