检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:殷鹏飞 吕国生 任桂林 YIN Pengfei;LV Guosheng;REN Guilin(Jinneng Holding Group Yanggao Thermal Power Co.,Ltd.,Datong,Shanxi 038100,China)
机构地区:[1]晋能控股集团阳高热电有限公司,山西大同038100
出 处:《山西电力》2023年第6期59-62,共4页Shanxi Electric Power
摘 要:某电厂自投运以来,一直存在空冷岛凝结水下降管振动的问题,严重影响了机组的安全运行。分析了凝结水下降管振动的原因,提出了通过增加空冷岛温度场,减少由温差引起的管道膨胀不均匀,从而降低凝结水下降管的振动;通过增加辅助抽真空泵,抽出更多的不凝结气体,增强换热效果,减少因凝结水汇流管膨胀不均匀而引发下降管振动的现象;通过增加新型导流装置降低下降管中凝结水的流速,防止下降管振动等改造措施。结果表明,改造措施能很好地控制凝结水下降管振动。Since a power plant is put into operation,there has always been a vibration of condensate downcomer of air-cooling island,which seriously affects the safe operation of the unit.In this paper,the causes of vibration of condensate downcomer are analyzed,and some reconstruction measures are proposed,such as,the vibration of the condensate downcomer can be reduced by increasing the temperature field of the air-cooling island and reducing the uneven expansion of the pipe caused by the temperature difference;the downcomer vibration caused by uneven expansion of condensate manifold can be reduced by adding auxiliary vacuum pump and extracting more non-condensing gas to enhance the heat transfer effect;the downcomer vibration can be prevented by adding a new type of diversion device to reduce the flow rate of condensate in the downcomer and so on.The results show that these reconstruction measures can control the vibration of condensate downcomer well.
关 键 词:空冷岛 温度场 新型导流装置 抽真空泵 管道振动
分 类 号:TM621[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222