某电厂脱硫系统节能降耗运行方式优化  被引量:3

Study on Optimization of Energy-saving and Consumption-reducing Operation Mode of Desulfurization System in a Power Plant

在线阅读下载全文

作  者:王晨光 WANG Chenguang(CHN Energy Zhejiang Ninghai Power Generation Co.,Ltd.,Ningbo,Zhejiang 315612,China)

机构地区:[1]国能浙江宁海发电有限公司,浙江宁波315612

出  处:《山西电力》2023年第6期63-67,共5页Shanxi Electric Power

摘  要:某电厂2号600 MW机组为降低脱硫系统运行期间系统能耗,通过对脱硫系统运行数据的分析、计算和诊断,结合设备和系统的设计资料,对影响脱硫系统能耗的各项参数进行优化调整,在现有边界条件下降低了脱硫系统耗电率,为节能优化运行提供了借鉴与参考。In order to reduce system energy consumption during operation of desulphurization system in a 600 MW unit of a power plant,the parameters that affect the energy consumption of desulfurization system are optimized and adjusted based on the analysis,calculation and diagnosis of the operation data of desulfurization system,combined with equipment and system design data.The power consumption rate of desulfurization system is reduced under the existing boundary conditions,which provides reference for energy-saving optimization operation.

关 键 词:机组负荷 脱硫系统 节能优化 浆液循环泵 

分 类 号:X773[环境科学与工程—环境工程]

 