硼氢化钾浓度对原子荧光法测定水中硒的影响  被引量:2

The Influence of the Concentration of Potassium Borohydride on the Determination of Selenium in Water by Atomic Fluorescence

在线阅读下载全文

作  者:蔡丽 张波浪 雷迅 Cai Li;Zhang Bolang;Lei Xun(Sichuan Neijiang Ecological Environment Monitoring Center Station,Neijiang Sichuan 641000,China;Neijiang City Ecological Environment Bureau,Neijiang Sichuan 641000,China)

机构地区:[1]四川省内江生态环境监测中心站,四川内江641100 [2]内江市生态环境局,四川内江641100

出  处:《山西化工》2023年第12期70-72,共3页Shanxi Chemical Industry

摘  要:主要采用原子荧光法测定不同浓度的硼氢化钾溶液对硒标准溶液荧光强度的影响,实验结果表明,硒的荧光强度会随着硼氢化钾浓度的增大而降低,硼氢化钾质量浓度为0.01 g/mL时,能节省测定硒元素的成本和提高测定系统的分辨力。In this paper,atomic fluorescence method was used to determine the effect of potassium borohydride solution with different concentrations on the fluorescence intensity of selenium standard solution.The experimental results show that the fluorescence intensity of selenium decreases with the increase of potassium borohydride concentration.When the concentration of potassium borohydride is 0.01 g/mL,the cost of selenium determination can be saved and the resolution of the determination system can be improved.

关 键 词:硼氢化钾 原子荧光  

分 类 号:O657.31[理学—分析化学]

 