某化工厂空分装置中冷冻水泵的故障分析及处理方法  被引量:2

Fault Analysis and Treatment Methods of the Chilled Water Pump in the Air Separation Unit of a Certain Chemical Plant

在线阅读下载全文

作  者:纪向宇 彭伟 Ji Xiangyu;Peng Wei(Shaanxi Yanchang Zhongmei Yulin Energy and Chemical Co.,Ltd.,Yulin Shaanxi 718500,China)

机构地区:[1]陕西延长中煤榆林能源化工股份有限公司,陕西榆林718500

出  处:《山西化工》2023年第12期107-108,136,共3页Shanxi Chemical Industry

摘  要:化工厂冷冻水泵因设备老化使用年限较长,导致出现驱动侧异常振动问题,该类型离心泵发生振动的原因是多方面、多种因素共同作用的结果,如不及时检修,会导致泵组设备运行故障。基于此,结合实际冷冻水泵振动故障,对泵组振动故障成因及解决措施进行分析处理,对检修工作经验进行总结,以期为相关工作提供参考借鉴。Due to the aging and long service life of the chemical plant's chilled water pump,abnormal vibration problems occur on the drive side.The vibration of this type of centrifugal pump is the result of the combined action of multiple factors.If not repaired in time,it can lead to operational failures of the pump equipment.Based on this,combined with actual vibration faults of refrigeration water pumps,the causes and solutions of pump group vibration faults are analyzed and processed,and the maintenance work experience is summarized,in order to provide reference for related work.

关 键 词:空分 离心泵 振动 故障诊断 

分 类 号:TQ53[化学工程—煤化学工程]

 