热用户室温不达标常见原因分析及解决方案  

Analysis and solution of common causes of substandard room temperature for hot users

在线阅读下载全文

作  者:赵晶 刘志超 王凯鹤 郝婧斯 王云鹏 ZHAO Jing;LIU Zhichao;WANG Kaihe;HAO Jingsi;WANG Yunpeng(Chengde Heating Group Co.,Ltd.,Chengde 067000,China)

机构地区:[1]承德热力集团有限责任公司,河北承德067000

出  处:《区域供热》2023年第6期91-96,146,共7页District Heating

摘  要:对4种常见室温不达的标类型及原因进行分析,并概述其诊断流程。以个别用户及整单元用户室温不达标处理为典型案例,对不热原因查找及处理方法进行重点分析,最后对室温不达标用户处理体系进行简要介绍。通过系统性分析与诊断,明确用户室温不达标的根本原因,有助于快速处理不热问题。This paper analyzes the four common types and the causes of room temperature non-compliance,and outlines the diagnosis process;which takes individual users and the entire unit buildings as typical cases for analyzing the non-heating causes and treatment methods.Lastly,a brief introduction of the room temperature non-compliance processing system of Chengde Heating Group is given.By conducting systematic analysis and diagnosis,identify the root cause of user room temperature non-compliance,in order to help quickly address the issue of insufficient heat.

关 键 词:室温不达标 水力失调 水循环不畅 

分 类 号:TU832[建筑科学—供热、供燃气、通风及空调工程]

 