测汞仪直接测定水中汞的不确定度评定  

Evaluation of Uncertainty for Direct Determination of Mercury in Water by Mercury Meter

在线阅读下载全文

作  者:金凯 JIN Kai(Jiangsu Junxin Xinhua Safety Science and Technology Co.,Ltd.,Zhangjiagang 215600,China)

机构地区:[1]江苏君信新华安全科技有限公司,江苏张家港215600

出  处:《现代食品》2023年第23期166-169,共4页Modern Food

摘  要:采用DMA-80测汞仪直接测定水中的汞,重复测定6次,计算实验标准差,分析实验过程引入的不确定来源,并对分量逐一进行不确定度评估,将这些不确定度分量进行合成,计算合成不确定度和扩展不确定度。结果表明标准曲线拟合、测量重复性和标准使用液及标准系列配制是测量不确定度的主要来源。Mercury in water was directly measured by DMA-80 mercury meter,and the measurement was repeated for 6 times.The standard deviation of the experiment was calculated,and the sources of uncertainty introduced in the experimental process were analyzed.The uncertainty of the components was evaluated one by one.The synthetic uncertainty and the extended uncertainty are calculated.The results show that standard curve fitting,measurement repeatability,standard solution and standard series preparation are the main sources of measurement uncertainty.

关 键 词:DMA-80测汞仪  不确定度 

分 类 号:O657.1[理学—分析化学]

 