上海市超低能耗住宅户式热泵冷暖两联供系统容量选型探讨  被引量:3

Study on the Capacity Selection of Heat Pump Dual-supply System for Ultra-low Energy Consumption Residential Buildings in Shanghai

在线阅读下载全文

作  者:刘心怡 王雅茹 赵恒谊 姚杨 倪龙 LIU Xinyi;WANG Yaru;ZHAO Hengyi;YAO Yang;NI Long(School of Architecture,Harbin Institute of Technology,Harbin 150001,China;Key Laboratory of Cold Region Urban and Rural Human Settlement Environments Science and Technology,Ministry of Industry and Information Technology,Harbin 150090,China;China Energy Conservation Association,Beijing 100029,China)

机构地区:[1]哈尔滨工业大学建筑学院,哈尔滨150001 [2]寒地城乡人居环境科学与技术工业和信息化部重点实验室,哈尔滨150090 [3]中国节能协会,北京100029

出  处:《建筑科学》2023年第12期136-145,共10页Building Science

基  金:国家自然科学基金项目“空气源热泵供暖系统功热转换与热输运规律研究”(52278100)。

摘  要:夏热冬冷地区超低能耗住宅多采用户式空气源热泵冷暖两联供系统为房间提供冷热量,且采用“部分时间、部分空间”室内环境营造模式,导致热泵系统容量选择有其特殊性。本文通过上海的一栋典型超低能耗住宅不同运行模式下的全年冷、热负荷模拟,分析户式热泵系统容量选择的方法。结果表明,与连续运行的负荷指标比较,间歇运行模式下,热泵系统室内末端负荷附加率为100%~200%,室外机负荷附加率为50%~60%,并发现虽然负荷指标增大,但间歇运行室内需能量可节约近20%。进而分析了户间传热、新风控制等因素对设备容量的影响,给出了适用于工程应用的户式热泵冷暖两联供系统容量选型的计算公式及负荷数据,为上海市及夏热冬冷地区超低能耗住宅的分散式冷热源设计提供参考。Ultra-low energy consumption residential buildings in hot summer and cold winter regions mostly use household air source heat pump cooling and heating system to provide cooling and heating for rooms,and adopt the"part time,part space"indoor environment construction mode,resulting in the unique selection of heat pump system capacity.This paper analyzed the capacity selection method of household heat pump systems through the simulation of annual cooling and heat loads under different operating modes of a typical ultra-low energy consumption house in Shanghai.The results show that,compared with the load index in continuous operation,the indoor terminal load addition rate of the heat pump system in intermittent operation mode is 100%~200%,and the outdoor unit load addition rate is 50%~60%.It is found that although the load index increases,the energy demand in intermittent operation rooms can be saved by nearly 20%.Then,the influence of factors such as inter-household heat transfer and ventilation control system on equipment capacity was analyzed,and the calculation formula and load data for the capacity selection of the heating and cooling system of household air source heat pump suitable for engineering applications were proposed,which can provide a reference for the distributed heating and cooling source design of ultra-low energy consumption residential buildings in Shanghai and the hot summer and cold winter regions.

关 键 词:超低能耗住宅 间歇运行 负荷附加率 户间传热 新风热回收 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象