检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:尹文杰[1] YIN Wenjie(CBMI Construction Company Limited,Beijing 100176,China)
机构地区:[1]中材建设有限公司,北京100176
出 处:《水泥技术》2024年第1期45-49,共5页Cement Technology
摘 要:某海外水泥项目熟料冷却风机锥形口流量测量装置选型偏小,导致冷却风机风量PID调节回路投运不稳,为满足PID投运要求,提高测量装置灵敏度,对冷却风机锥形口流量测量装置进行了改造。详细介绍了锥形口流量测量装置现场改造及制作安装要求、流量系数计算方法、现场标定结果等。改造后,在设计风量为29 965m^(3)/h时,差压值达373Pa,管道系统静压增加了248Pa,提高了流量测量装置的风量检测灵敏度,保证了PID调节回路的稳定自动调节。The section of cone-shaped nozzle air flow measurement device for clinker cooling fan is small for an oversea cement project,resulting in the unstable operation of PID loop for the cooling fan air volume,in order to meet the PID operation requirements and improve the sensitivity of the measurement device,the cone-shaped nozzle flow measurement device of cooling fan has been modified.This paper introduces the modification method and installation requirements of the coneshaped nozzle flow measurement device,and the calculation method of the flow coefficient and the field calibration result.The differential pressure value reaches 373Pa after modification when the design air volume is 29965 m^(3)/h.The static pressure of the pipeline system is increased by 248Pa,and the sensitivity of the flow measurement device is improved,ensuring the stable and automatic adjustment of the PID loop.
分 类 号:TQ172.622.4[化学工程—水泥工业]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.232