作 者:韩周洋 刘昌威 孙丹 HAN Zhou-yang;LIU Chang-wei;SUN Dan(Suqian Environmental Monitoring Center of Jiangsu Province,Suqian Jiangsu 223800,China)
机构地区:[1]江苏省宿迁环境监测中心,江苏宿迁223800
出 处:《辽宁化工》2024年第1期158-161,共4页Liaoning Chemical Industry
摘 要:利用涂渍2,4-二硝基苯肼(DNPH)硅胶填充管采集环境空气中醛酮类化合物,建立了高效液相色谱法测定环境空气中醛酮类的方法。结果表明:该测试方法呈现良好的线性关系,线性系数的范围在0.9998~1.0000之间;方法检出限范围为0.65~2.46μg·m^(-3),测定下限为2.61~9.85μg·m^(-3);低、中、高浓度相对标准偏差范围分别为0.9%~8.5%、0.5%~3.6%、0.6%~2.8%;实际样品加标回收率范围为94.6%~113%。该方法稳定性好,操作简单,灵敏度高,满足于环境空气中醛酮类测定。A method for the determination of carbonyl compounds in ambient air by high performance liquid chromatography(HPLC)was established by using 2,4-dinitrophenylhydrazine(DNPH)coated silica gel filled tubes to collect carbonyl compounds in ambient air.The results showed that the test method had a good linear relationship,and the linear coefficient ranged from 0.9998 to 1.000;The detection limit of the method was 0.65~2.46μg·m^(-3),the lower limit of determination was 2.61~9.85μg·m^(-3);The relative standard deviations of low,medium and high mass concentrations were 0.9%~8.5%,0.5%~3.6%and 0.6%~2.8%respectively;The actual sample spiking recovery range was 89.8%~116%.The method has the advantages of good stability,simple operation and high sensitivity,and is suitable for the determination of aldehydes and ketones in ambient air.