液质联用法测定十一味参芪片中马兜铃酸Ⅰ、马兜铃酸Ⅳa和马兜铃内酰胺Ⅰ  被引量:1

Determination of Aristolochic AcidⅠ,Aristolochic AcidⅣa,and AristolactamⅠin Shiyiwei Shenqi Tablets by Liquid Chromatography-mass Spectrometry

在线阅读下载全文

作  者:覃丽郦 何颂华 白桂昌 罗轶 QIN Li-li;HE Song-huaa;BAI Gui-chang;LUO Yi(NMPA Key Laboratory for Quality Monitoring and Evaluation of Traditional Chinese Medicine,Chinese Material Medica,Guangxi Institute for Food and Drug Control,Nanning 530021,China)

机构地区:[1]广西壮族自治区食品药品检验所国家药品监督管理局中药材质量监测与评价重点实验室,广西南宁530021

出  处:《中国现代中药》2023年第12期2606-2611,共6页Modern Chinese Medicine

摘  要:目的:建立十一味参芪片中马兜铃酸Ⅰ、马兜铃酸Ⅳa和马兜铃内酰胺Ⅰ的液相色谱-质谱法(LCMS)检测分析方法。方法:Kromasil Proshell C18色谱柱(100 mm×2.1 mm,2.5μm),以乙腈-0.1%乙酸水溶液(含10 mmol·L^(-1)乙酸铵)为流动相,梯度洗脱,流速0.3 mL·min^(-1);多反应监测模式,马兜铃酸Ⅰ为m/z 359.1→298.1(定量)和m/z 359.1→296.1(定性),马兜铃酸Ⅳa为m/z 375.1→312.2(定量)和m/z 375.1→297.2(定性),马兜铃内酰胺Ⅰ为m/z 294.1→279.0(定量)和m/z 294.1→251.1(定性),建立十一味参芪片中3个马兜铃酸类成分的LC-MS,在方法学验证的基础上对所有样品进行检测分析。结果:马兜铃酸Ⅰ、马兜铃酸Ⅳa和马兜铃内酰胺Ⅰ进样量分别在2.0197~100.9829、1.9478~116.8656、1.9718~98.5880 pg时线性关系良好(r>0.999),定量限分别为1、6、2 pg,加样回收率分别为92.95%(RSD为2.28%)、80.09%(RSD为4.16%)、104.89%(RSD为3.24%)。14批十一味参芪片样品中马兜铃酸Ⅰ、马兜铃酸Ⅳa和马兜铃内酰胺Ⅰ的检出量分别为21.0~47.6、185.0~506.1、164.4~426.0 ng·g^(-1)。结论:所建立的方法快速、准确、灵敏、可靠,能够用于十一味参芪片中上述马兜铃酸类成分的筛查与分析,可为其安全性有关成分研究提供参考。Objective:To establish a liquid chromatography-mass spectrometry(LC-MS)method for the detection and analysis of aristolochic acidⅠ,aristolochic acidⅣa,and aristolactamⅠin Shiyiwei Shenqi Tablets.Methods:A Kromasil Proshell C18 chromatographic column(100 mm×2.1 mm,2.5μm)was used with acetonitrile-0.1%acetic acid solution(containing 10 mmol·L^(-1)ammonium acetate)as the mobile phase,using a gradient elution at a flow rate of 0.3 mL·min^(-1).Multiple reaction monitoring mode was employed with m/z 359.1→298.1(quantitative)and m/z 359.1→296.1(qualitative)for aristolochic acidⅠ,m/z 375.1→312.2(quantitative)and m/z 375.1→297.2(qualitative)for aristolochic acidⅣa,and m/z 294.1→279.0(quantitative)and m/z 294.1→251.1(qualitative)for aristolactamⅠ.The LC-MS method for the three components in Shiyiwei Shenqi Tablets was established,and all samples were subsequently subjected to detection and analysis based on methodological verification.Results:The linear relations of aristolochic acidⅠ,aristolochic acidⅣa,and aristolactamⅠwere good with injection volumes of 2.0197-100.9829,1.9478-116.8656,and 1.9718-98.5880 pg,respectively,with correlation coefficients(r)greater than 0.999.The respective limits of quantification were 1,6,2 pg.The recoveries of the three components were 92.95%(RSD 2.28%),80.09%(RSD 4.16%),and 104.89%(RSD 3.24%),respectively.The detected levels of aristolochic acidⅠ,aristolochic acidⅣa,and aristolactamⅠin the 14 batches of Shiyiwei Shenqi Tablets were 21.0-47.6,185.0-506.1,and 164.4-426.0 ng·g^(-1),respectively.Conclusion:The established LC-MS method is rapid,accurate,sensitive,and reliable,and can be used for the screening and analysis of the above components in Shiyiwei Shenqi Tablets,providing reference data for research on their safety-related components.

关 键 词:十一味参芪片 马兜铃酸Ⅰ 马兜铃酸Ⅳa 马兜铃内酰胺Ⅰ 液相色谱-质谱法 

分 类 号:R286[医药卫生—中药学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象