检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王洋洋 林童 丛志锋 房鸿 张志刚 张亲亲 WANG Yangyang;LIN Tong;CONG Zhifeng;FANG Hong;ZHANG Zhigang;ZHANG Qinqin(Liaoning Provincial Key Laboratory of Chemical Separation Technology,School of Chemical Engineering,Shenyang University of Chemical Technology,Shenyang 110142,China)
机构地区:[1]沈阳化工大学化学工程学院辽宁省化工分离技术重点实验室,辽宁沈阳110142
出 处:《石油化工》2024年第1期51-55,共5页Petrochemical Technology
基 金:国家自然科学基金项目(21978173,22108174);辽宁省自然科学基金项目(2021-NLTS-12-05);沈阳化工大学优秀青年基金项目(2019YQ002);辽宁省教育厅面上项目(LJKZ0443)。
摘 要:在常压、303.15 K条件下,以离子液体(IL)1-乙基-3-甲基咪唑磷酸二氢盐([EMIM][DHP])、1-丙基-3-甲基咪唑磷酸二氢盐([PMIM][DHP])、1-丁基-3-甲基咪唑磷酸二氢盐([BMIM][DHP])为萃取剂,测定了乙醇-碳酸甲乙酯(EMC)-IL体系的液液相平衡(LLE)数据,分别计算了不同IL对乙醇-EMC体系的分配系数和选择性系数,并研究了IL对乙醇-EMC共沸体系相平衡行为的影响。采用Aspen Plus软件中的NRTL模型对乙醇-EMC-IL体系的LLE数据进行模型关联,得到相应的非随机参数和二元相互作用参数,为IL萃取分离乙醇-EMC的工艺设计奠定基础。实验结果表明,以[EMIM][DHP],[PMIM][DHP],[BMIM][DHP]为萃取剂分离乙醇-EMC共沸体系的选择性系数均大于1,3种ILs都具有良好的分离效果,其中,[EMIM][DHP]的选择性系数最高;采用NRTL模型关联得到的计算值与实验值的均方根偏差小于5%,表明NRTL模型关联乙醇-EMC-ILs三元体系的LLE数据准确性较好。Using ionic liquids(IL)1-ethyl-3-methylimidazole dihydrogen phosphate([EMIM][DHP]),1-propyl-3-methylimidazole dihydrogen phosphate([PMIM][DHP])and 1-butyl-3-methylimidazole dihydrogen phosphate([BMIM][DHP])as extractants,the liquid-liquid equilibrium(LLE)data of ethanol-methyl ethyl carbonate(EMC)-IL system were determined at atmospheric pressure and 303.15 K.The distribution coefficients and selectivity coefficients of different ILs for the ethanol-EMC system were calculated respectively,and the effect of IL on the phase equilibrium behavior of the ethanol-EMC azeotropic system was studied.The NRTL model in Aspen Plus software was used to correlate the LLE data of the ethanol-EMC-IL system,and the corresponding non-random parameters and binary interaction parameters were obtained,laying the foundation for the process design for ethanol-EMC separation with IL.The experimental results show that the selectivity coefficients of ethanol-EMC azeotrope systems using[EMIM][DHP],[PMIM][DHP],[BMIM][DHP]as extractant are all greater than 1,and the selectivity coefficients of[EMIM][DHP]are the highest.The root-mean-square deviation between the calculated values and the experimental values using the NRTL model is less than 5%,indicating that the accuracy of the LLE data of ethanol-EMC-ILs ternary system is good.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.15.5.184