检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:魏滨[1] 常通[1] 王韬 WEI Bin;CHANG Tong;WANG Tao(Zibo Center for Disease Control and Prevention,Zibo Key Laboratory for Monitoring and Analysis of Environmental Organic Pollution and Population Health,Zibo Shandong,255026,China)
机构地区:[1]淄博市疾病预防控制中心,淄博市环境有机污染与人群健康监测分析重点实验室,山东淄博255026
出 处:《职业与健康》2023年第23期3200-3205,共6页Occupation and Health
基 金:2018年淄博市重点研发计划项目(2018kj010115)。
摘 要:目的 研究电感耦合等离子体发射光谱法(inductively coupled plasma atomic emission spectrometry,ICP-OES)和电感耦合等离子体质谱法(inductively coupled plasma mass spectrometry,ICP-MS)测定食品中铝结果的一致性。方法 取1份大米粉称取0.2~0.3 g加入8 mL硝酸微波消解,超声赶酸后纯水定量转移入25 mL容量瓶中,分别用ICP-OES和ICPMS进行测定,对2种方法测定结果进行不确定度评定。结果 使用ICP-OES法测定结果为16.0 mg/kg,进行不确定度评定后的结果及其扩展不确定度为(12.1±3.6)mg/kg,k=2。使用ICP-MS法样品测定结果为12.4 mg/kg,进行不确定度评定后其结果及其扩展不确定度为(12.4±5.4)mg/kg。ICP-OES法测定结果的可能分布范围为8.5~15.7 mg/kg,ICP-MS法测量结果的可能分布范围为7.0~17.8 mg/kg,ICP-OES法结果分布完全包含于ICP-MS法的结果分布范围中。结论 进行不确定度评定并进行加标回收率校正后ICP-OES和ICP-MS测定食品中铝的结果具有一致性。Objective To study the consistency between the results of inductively coupled plasma atomic emission spectrometry(ICP-OES) and inductively coupled plasma mass spectrometry(ICP-MS) in the determination of aluminum in food. Methods 0.2-0.3 g of a portion of rice flour was weighed and added into 8 mL nitric acid for microwave digestion. After ultrasonic acid removal,the samples were quantitatively transferred into a 25 mL volumetric flask with pure water,and determined by ICP-OES and ICP-MS respectively. The uncertainty of the results of the two methods was evaluated. Results The determination result using ICP-OES was 16.0 mg/kg,and the uncertainty evaluation showed that the result and the expanded uncertainty was(12.1±3.6)mg/kg,k =2. The determination result using ICP-MS was 12.4 mg/kg,and the uncertainty evaluation showed that the result and the expanded uncertainty was(12.4±5.4)mg/kg. The possible distribution range of the results measured by ICP-OES method was 8.5-15.7 mg/kg,and the possible distribution range of the results measured by ICP-MS was 7.0-17.8 mg/kg. The distribution of the results measured by ICP-OES method was completely included in the distribution range of the results measured by ICP-MS method. Conclusion The results of determination of aluminum in food by ICP-OES and ICP-MS are consistent after uncertainty evaluation and recovery correction.
关 键 词:电感耦合等离子体发射光谱法 电感耦合等离子体质谱法 铝 不确定度评定 一致性
分 类 号:R115[医药卫生—公共卫生与预防医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145