钴靶池边活度测量  

Poolside Activity Measurement of Cobalt Target

在线阅读下载全文

作  者:殷振国 连琦 张平 徐北 王明明 冯五洲 颜田玉 YIN Zhenguo;LIAN Qi;ZHANG Ping;XU Bei;WANG Mingming;FENG Wuzhou;YAN Tianyu(China Nuclear Power Technology Research Institute,Shenzhen 518031,China;Shanxi Weifeng Instrument Inc.,Xi’an 710199,China)

机构地区:[1]中广核研究院有限公司,深圳518031 [2]陕西卫峰核电子有限公司,西安710199

出  处:《同位素》2024年第1期17-23,共7页Journal of Isotopes

摘  要:为了获取压水堆经过一个循环辐照后的钴靶活度数据,利用丙氨酸剂量片测量位于水下的钴靶剂量场分布,通过蒙特卡罗(MCNP)计算修正钴靶结构、水介质、测量装置、操作以及环境的影响。结果表明,从水下测量的钴靶活度数据与理论计算值相符,不确定度为6.5%。从实验与蒙特卡罗计算两方面确认了方法与装置的可行性。To obtain cobalt target activity data after a cycle of irradiation in a pressurized water reactor,the cobalt target dose distribution was measured underwater using alanine dosimeters.The effects of cobalt target structure,water medium,measurement device,operation,and environment were corrected using Monte Carlo calculations.The feasibility of the method and device was confirmed through both experimental and Monte Carlo comparison.The underwater measurement data of cobalt target activity matches the theoretical calculated values,with an uncertainty of 6.5%.

关 键 词:^(60)Co 丙氨酸 MCNP 乏燃料水池 

分 类 号:TL72[核科学技术—辐射防护及环境保护]

 