检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王晶 何丽霞[1] 邵婕文[1] 李育蓉 WANG Jing;HE Lixia;SHAO Jiewen;LI Yurong(Department of Radiochemistry,China Institute of Atomic Energy,Beijing 102413,China)
机构地区:[1]中国原子能科学研究院放射化学研究所,北京102413
出 处:《原子能科学技术》2024年第2期489-497,共9页Atomic Energy Science and Technology
摘 要:定量测量工艺设备中的滞留量是核设施核材料测量的技术难点之一,对辐射防护、核材料临界安全和核材料闭合衡算具有重要意义。在核材料工艺生产线上,阀门与管道的连接方式不利于取样,因此,非破坏性分析方法更适合用于开展阀门中滞留量的测量。本文采用无源效率刻度,针对球阀和蝶阀这两种最常见的阀门,建立了探测器全能峰绝对探测效率分析模型。运用坐标变换方法,实现了阀门分析模型的快速建立。在实验室条件下采用标准点源和铀样品进行了初步验证,铀样品中235 U含量的测量分析结果和标称值的相对偏差小于15%。坐标变换方法可快速准确地建立各种类型阀门的分析模型,为测量分析模型的建立提供了简便易行的解决方案。During the production and operation of some bulk handling facilities,nuclear material deposits remaining after cleaning in and about process equipment,interconnecting piping,filters and adjacent work area or equipment,which is called holdup.In order to meet the requirements of nuclear material accounting management,the physical inventory of nuclear materials shall be carried out according to the specified frequency,and the amount of nuclear materials shall be the measured value.Quantitative measurement of holdup in equipment is one of the technical difficulties in nuclear material measurement for nuclear facilities.Holdup measurement is important for radiation protection,critical safety and nuclear material management.The valve is a key component to control the material transfer in the process of nuclear material production.The valve is welded to pipe,which is not conducive to sampling.In this paper,mass of uranium in the valve was measured byγ-ray spectroscopy.It is necessary to study absolute detection efficiencies of the detector for known source distribution.Firstly,the passive efficiency calibration was selected to simulate the absolute detection efficiencies.Analysis models consist of detector model and valve models,they were placed under the same observation system by the transforming coordinate method.Analysis models of detector and valves were built based on information of the detector and design drawing of the valves.Two point sources,57 Co and 137 Cs,were used to verify the model.Under the combination of different crystal radius and length parameters,the absolute detection efficiencies for full-energyγ-rays peak were simulated.The crystal parameters of the LaBr 3 detector were adjusted.The root mean square of the relative deviation between the simulation results and the experimental results was calculated.The crystal parameters with the smallest root mean square are the best parameters.The relative deviation between the experimental results and Monte Carlo simulation results for point sources is with
分 类 号:TL81[核科学技术—核技术及应用]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.144.143.110