检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:赵书涛[1] 黄伟杰 刘会兰[1] 杨嘉睿 刘云鹏[1] ZHAO Shutao;HUANG Weijie;LIU Huian;YANG Jiarui;LIU Yunpeng(Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense,North China Electric Power University,Baoding 071003,China;Economic and Technological Research Institute,State Grid Zhejiang Electric Power Co.,Ltd.,Hangzhou 310000,China)
机构地区:[1]华北电力大学河北省输变电设备安全防御重点实验室,保定071003 [2]国网浙江省电力有限公司经济技术研究院,杭州310000
出 处:《高电压技术》2024年第2期489-502,共14页High Voltage Engineering
基 金:国网浙江省电力有限公司科技项目(5211JY22000V)。
摘 要:随着高压断路器接近设计寿命年限其触头烧蚀情况越来越严重,评估高压断路器电寿命可提高利用效率同时保证其运行可靠性。根据近些年有关开关电器电寿命相关文献,首先从触头烧蚀数学模型出发剖析了断路器电寿命终结物理过程;然后对比了目前常用的断路器电寿命评估方法优缺点,指出数据模型是驱动设备寿命准确评估的关键,并借鉴其他类型开关电器电寿命相关研究为高压断路器靠性评估开拓了思路。最后指出高压断路器电寿命预测所面临挑战以及研究方向。As high-voltage circuit breakers approach their design life and their contact ablation becomes more and more serious,evaluating the electrical life of high-voltage circuit breakers can improve the utilization efficiency and ensure their operational reliability.According to the literature related to the electrical life of switchgear in recent years,the phys-ical process of the end of electrical life of the circuit breaker is analyzed from the mathematical model of contact ablation.Then,the advantages and disadvantages of the current commonly-used assessment methods for circuit breaker electrical life are compared,and it is pointed out that the data model is the key to the accurate evaluation of the life of drive equip-ment,and the research on the electrical life of other types of switchgear electrical appliances is used to open up ideas for the reliability evaluation of high-voltage circuit breakers.Finally,the challenges and research directions of electrical life prediction of high-voltage circuit breakers are pointed out.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.38