智能手机图形比色法快速测定水中的高氯酸盐  被引量:3

Rapid Determination of Perchlorate Concentration inWater Based on Smartphone

在线阅读下载全文

作  者:陈沛宇 罗琳[1] 杨远[1] 宾明杰 CHEN Peiyu;LUO Lin;YANG Yuan;BIN Mingjie(College of the Environment and Ecology,Hunan Agricultural University,Changsha,Hunan 410128,China)

机构地区:[1]湖南农业大学环境与生态学院,长沙410128

出  处:《中国无机分析化学》2024年第4期379-385,共7页Chinese Journal of Inorganic Analytical Chemistry

基  金:湖南省重点研发计划项目(2023NK2029);国家自然科学基金资助项目(42107308,42077308);中国博士后基金资助项目(2019M652768)。

摘  要:高氯酸盐是水环境中一种典型的难降解的持久性无机污染物,具有高度水溶性及扩散性。地表水及地下水中的高氯酸盐可以通过多种方式保存在食物和饮用水中,对人体健康造成严重危害。针对传统的高氯酸盐检测技术操作复杂、检测周期长、成本高且不便于即时检测等问题,建立了一种智能手机快速测定高氯酸盐含量的新方法,以充分发挥其简便、准确、快速现场检测水中高氯酸盐的优势。采用由3D打印箱、扩散板、补光灯和智能手机构建的数字图像比色装置完成水中高氯酸盐浓度的快速检测,考察手机型号、光源、干扰离子对数字图像比色装置检测结果R(红)、G(绿)、B(蓝)值的影响。结果表明,以R-通道数字信号值作为测定值时,高氯酸盐在0~600μg/L呈良好的线性关系,线性方程为y=-0.1505 x+150.66,相关系数为R^(2)=0.995,加标回收率为96.0%~107%,检出限为27.7μg/L,测定限为88μg/L。选择白光、iPhone 11检测两组不同浓度高氯酸盐的实际水样,以探究重现性,测定结果的相对标准偏差为3.2%~4.0%,回收率为95.0%~107%,方法具有一定的可行性和准确性,为现场快速测定水中高氯酸盐提供了一个新思路。Perchlorate is a typical persistent inorganic pollutant that is difficult to degrade in the aquatic environment,with high water solubility and diffusivity.Perchlorates in surface water and groundwater can be stored in food and drinking water in various ways,posing a serious threat to human health.In response to the problems of complex operation,long detection cycle,high cost,and inconvenient real-time detection of traditional perchlorate detection technology,a new method for rapid determination of perchlorate content using smartphone,fully leveraging its advantages of simple,accurate,and fast on-site detection of water perchlorate was proposed.In this study,a digital image colorimetric device constructed by 3D printing box,diffusion plate,fill light and smart phone was used to achieve rapid detection of perchlorate concentration in water.The effects of mobile phone model,light source and interfering ions on the R(red),G(green)and B(blue)values of the digital image colorimetric device were discussed.The results showed that when the R-channel digital signal value was taken as the determination value,the perchlorate showed a good linear relationship in the concentration range of 0—600μg/L.The linear equation was y=-0.1505 x+150.66,the correlation coefficient(R^(2))was 0.995,and the recovery was 96.0%—107%.The limit of detection was 27.7μg/L,and the limit of determination was 88μg/L.Two sets of actual water samples with different concentrations of perchlorate were tested using white light and iPhone 11 to explore the reproducibility.The relative standard deviation of the test results was only 3.2%to 4.0%,and the sample recovery ranged from 95.0%to 107%.This method has certain feasibility and accuracy,and provides a new idea for the on-site rapid determination of perchlorate in water.

关 键 词:高氯酸盐 数字图像 亚甲基蓝 智能手机 

分 类 号:O657.32[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象