沿江泵站电机定子和转子轴向偏差的处理分析  

Treatment of axial deviation in motor stator and rotor of riverside pumping stations

在线阅读下载全文

作  者:陈洋 王正飞 朱海清 CHEN Yang;WANG Zhengfei;ZHU Haiqing(Shanghai Branch of Yangtze River Survey,Planning,Design and Research Co.,Ltd.,Shanghai 200439,China;Changshu Water Conservancy Project Construction Management Division,Changshu 215500,China)

机构地区:[1]长江勘测规划设计研究有限责任公司上海分公司,上海200439 [2]常熟市水利工程建设管理处,江苏常熟215500

出  处:《水利建设与管理》2023年第10期49-52,37,共5页Water Conservancy Construction and Management

摘  要:为解决某立式X流道双向泵站配套电机安装过程中推力头卡阻的问题,采用理论分析结合现场量测的方法进行了分析。发现原因是定、转子生产中几何中心线出现了10mm偏差。为此针对不同安装整改方案进行了利害分析,确定了较优的整改措施。结果表明:整改方案成功解决了水泵电机的安装问题,满足了立式轴流泵机组安装规范要求,安装后经试运行检验机组性能正常。本文的整改思路和措施可为类似工程机组的安装方案借鉴,也可供电机产品设计参考。To address the issue of thrust head obstruction during the installation of a certain vertical X-flow dual-channel pumping station and its accompanying motor,a combination of theoretical analysis and on-site measurements was employed.It was discovered that the root cause was a 10mm deviation in the geometric center line of the stator and rotor during production.Consequently,various corrective installation schemes were analyzed for their advantages and disadvantages,leading to the identification of an optimal corrective measure.The results indicate that the corrective measure successfully resolved the installation problem of the pump motor,meeting the installation standards for the vertical shaft pump unit.Following installation,the unit’s performance was verified as normal during trial operation.The corrective approach and measures proposed in this study serve as a valuable reference for similar engineering unit installations and provide essential insights for the design of motor products.

关 键 词:X流道 双向泵站 同步电机 转子 挡油板 

分 类 号:TV675[水利工程—水利水电工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象