硅钢含铬绝缘涂层的红外光谱研究  

Infrared Spectroscopy Study of Chromium-Containing Insulating Coatings on Silicon Steel

在线阅读下载全文

作  者:李登峰[1] 洪涛[1] 王波[1] LI Dengfeng;HONG Tao;WANG Bo(Central Research Institute of Baoshan Iron and Steel Co.,Ltd.,Shanghai 201900,China)

机构地区:[1]宝山钢铁股份有限公司中央研究院,上海201900

出  处:《电工材料》2024年第1期34-36,40,共4页Electrical Engineering Materials

摘  要:基于傅里叶变换衰减全反射红外光谱法(ATR-FTIR)研究不同烘烤固化方式和工艺对无取向硅钢含铬绝缘涂层部分性能的变动,讨论了涂层厚度、红外加热方式和固化程度对含铬涂层红外光谱的影响。结果发现:ATR-FTIR可作为硅钢含铬绝缘涂层测试表征的重要方法,可规避涂层厚度、色泽波动所致影响;红外谱图中915 cm-1附近的吸收峰,可作为涂层中是否含有[Cr6+]的判断依据;1585 cm-1附近的吸收峰可作为硅钢含铬涂层成膜物质(丙烯酸树脂与三价铬交联形成复合盐)的特征峰参照。Based on Fourier Transform Attenuated Total Reflection Infrared Spectroscopy(ATR-FTIR),the changes of different curing methods and processes on the properties of non-oriented silicon steel chromiumcontaining insulating coatings were studied.Effects of coating thickness,infrared heating method and curing degree on the IR spectrum of Cr-coatings were discussed.The results show that ATR-FTIR can be used as an important method for the characterization of Cr-containing insulating coatings on silicon steel,which can avoid the influence of coating thickness and color fluctuations;the absorption peak near 915 cm-1 in the IR spectrum can be used as the basis for judging whether the coating contains[Cr6+];the peak near 1585 cm-1 can be used as reference for the characteristic peak of the film-forming substance of the Crcoating on silicon steel(acrylic resin cross-linked with trivalent chromium to form a complex salt).

关 键 词:无取向硅钢 含铬涂层 衰减全反射红外光谱法 

分 类 号:TM275[一般工业技术—材料科学与工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象