Numerical simulations for radon migration and exhalation behavior during measuring radon exhalation rate with closed-loop method  

在线阅读下载全文

作  者:Ming Xia Yong-Jun Ye Shu-Yuan Liu 

机构地区:[1]School of Resources Environment and Safety Engineering,University of South China,Hengyang 421001,China [2]Key Discipline Laboratory for National Defense for Biotechnology in Uranium Mining and Hydrometallurgy,University of South China,Hengyang 421001,China

出  处:《Nuclear Science and Techniques》2024年第1期81-95,共15页核技术(英文)

基  金:This work was supported by the National Natural Science Foundation of China(No.11575080);the National Natural Science Foundation of Hunan Province,China(No.2022JJ30482);the Hunan Provincial Innovation Foundation for Postgraduates(No.QL20220206).

摘  要:Accurate measurements of the radon exhalation rate help identify and evaluate radon risk regions in the environment.Among these measurement methods,the closed-loop method is frequently used.However,traditional experiments are insufficient or cannot analyze the radon migration and exhalation patterns at the gas–solid interface in the accumulation chamber.The CFD-based technique was applied to predict the radon concentration distribution in a limited space,allowing radon accumulation and exhalation inside the chamber intuitively and visually.In this study,three radon exhalation rates were defined,and two structural ventilation tubes were designed for the chamber.The consistency of the simulated results with the variation in the radon exhalation rate in a previous experiment or analytical solution was verified.The effects of the vent tube structure and flow rate on the radon uniformity in the chamber;permeability,insertion depth,and flow rate on the radon exhalation rate and the effective diffusion coefficient on back-diffusion were investigated.Based on the results,increasing the inser-tion depth from 1 to 5 cm decreased the effective decay constant by 19.55%,whereas the curve-fitted radon exhalation rate decreased(lower than the initial value)as the deviation from the initial value increased by approximately 7%.Increasing the effective diffusion coefficient from 2.77×10^(-7) to 7.77×10^(-6) m^(2) s^(-1) made the deviation expand from 2.14 to 15.96%.The conclusion is that an increased insertion depth helps reduce leakage in the chamber,subject to notable back-diffusion,and that the closed-loop method is reasonably used for porous media with a low effective diffusion coefficient in view of the back-diffusion effect.The CFD-based simulation is expected to provide guidance for the optimization of the radon exhalation rate measurement method and,thus,the accurate measurement of the radon exhalation rate.

关 键 词:Radon exhalation Numerical simulation Accumulation chamber 

分 类 号:X837[环境科学与工程—环境工程]

 