高效液相色谱法测定皮革中的双酚A、双酚F和双酚S  

Determination of Bisphenol A,Bisphenol F and Bisphenol S in Leather by HPLC

在线阅读下载全文

作  者:肖湾 马红青[1] 赵霞[1] XIAO Wan;MA Hongqing;ZHAO Xia(Shanghai Institute of Quality Inspection and Technical Research,Shanghai 201114)

机构地区:[1]上海市质量监督检验技术研究院,上海201114

出  处:《皮革与化工》2024年第1期15-17,22,共4页Leather And Chemicals

摘  要:建立了一种测定皮革中双酚A、双酚F和双酚S含量的分析方法。皮革样品经甲醇超声提取、旋转蒸发仪浓缩后,在277 nm波长条件下,使用高效液相色谱仪进行分析,经二极管阵列器检测,甲醇-水溶液洗脱后,外标法进行定量。结果显示,双酚A、双酚F和双酚S在1 mg·L^(-1)~30 mg·L^(-1)的范围内线性相关系数均大于0.9995,检出限均小于0.64 mg·kg^(-1),高、中、低三个水平加标回收率范围为85.8%~97.1%,相对标准偏差为0.11%~2.22%,满足检测要求。An analytical method for the determination of bisphenol A,bisphenol F and bisphenol S in leather was established.Leather samples were extracted by methanol ultrasound,concentrated by rotary evaporator,analyzed by HPLC at 277 nm wavelength,detected by diode array,eluted by methanol-water solution,and quantified by external standard method.The results showed that the linear correlation coefficients of bisphenol A,bisphenol F and bisphenol S in the range of 1 mg·L^(-1)~30 mg·L^(-1) were greater than 0.9995,the detection limits were less than 0.64 mg·kg^(-1),the recovery rates of spiked standard at high,middle and low levels were 85.8%~97.1%,and the relative standard deviations were 0.11%~2.22%,which met the detection requirements.

关 键 词:皮革 双酚A 双酚F 双酚S 测定 

分 类 号:TS57[轻工技术与工程—皮革化学与工程]

 