端头固定方式对架空绝缘电缆拉断力的影响  

Influence of End Fixing Method on Breaking Force of Overhead Insulated Cable

在线阅读下载全文

作  者:刘磊 荔建荣 孔凯[3] LIU Lei;LI Jianrong;KONG Kai(Jiangsu Zhuying Special Cable Co.,Ltd.,Yixing 214200,China;Guangdong Jianbao Cable Co.,Ltd.,Guangzhou 511300,China;Jiangsu Product Quality Supervision and Inspection Research Institute,Yixing 214205,China)

机构地区:[1]江苏珠影特种电缆有限公司,宜兴214200 [2]广东坚宝电缆有限公司,广州511300 [3]江苏省产品质量监督检验研究院,宜兴214205

出  处:《电线电缆》2024年第1期40-42,共3页Wire & Cable

摘  要:研究了在采用低熔点合金浇注法、夹具法、预绞丝固定法和金具压接法等4种端头固定方式下,1 kV架空绝缘电缆导体对架空绝缘电缆拉断力的影响,并对其试验结果进行了对比。最后,结合不同端头固定方式的优缺点,确定夹具法为最佳的端头固定方式。Effect of four end fixing methods,including low melting point alloy casting,clamp method,pre-twisted wire fixing method and fitting crimping method on tensile strength of 1 kV overhead insulated cable conductors was studied,and their test results were compared.Results showed that clamp method was determined to be the best end fixing method by analyzing and combining the advantages and disadvantages of different fixing methods.

关 键 词:架空绝缘电缆 拉断力 端头固定 

分 类 号:TM247.9[一般工业技术—材料科学与工程]

 