作 者:李胤 韦应靖[1,2] 王川 张大可 王弘昱 陈双强 LI Yin;WEI Yingjing;WANG Chuan;ZHANG Dake;WANG Hongyu;CHEN Shuangqiang(Shanxi Key Laboratory for Radiation Safety and Protection,China Institute for Radiation Protection,Taiyuan 030006,China;Tsinghua University,Beijing 100084,China;Nuclear Power Operations Research Institute,Shanghai 200126,China)
机构地区:[1]中国辐射防护研究院,辐射安全与防护山西省重点实验室,山西太原030006 [2]清华大学,北京100084 [3]核电运行研究(上海)有限公司,上海200126
出 处:《中国环境监测》2024年第1期233-240,共8页Environmental Monitoring in China
摘 要:参考计量技术规范《固定式环境γ辐射空气比释动能(率)仪现场校准规范》(JJF 1733—2018),对辐射环境空气自动监测站78台高气压电离室开展辐射特性测试。现场校准方面,仅88%的电离室满足1±0.2的响应范围要求;78台电离室的重复性均不超过1%,响应的非线性均不超过6.5%,符合规范要求。针对电离室开展辐射性能测试,发现电离室在9.0×10^(-2)~1.0×10^(9)μGy/h范围内的响应均不超过1±0.2;电离室对164 keV以上的光子的能量响应趋于1.0,对60 keV以下的光子无响应能力,而当光子能量在60~164 keV范围内时,响应曲线会因γ光子与电离室内部惰性气体的光电效应出现“鼓包”;电离室不具备对核临界事故脉冲辐射的监测与警示能力;电离室能够在2 s内给出测量范围内的准确示值,但在分段电压的交界处,响应时间会延长至180~360 s;电离室的响应受环境温度、湿度变化的影响大小不足±0.01,表明电离室的环境适应性优良。In this paper,the radiation characteristics of 78 high pressure ionization chambers are tested with reference to the metrological technical specification JJF 1733-2018.In the field calibration,88%of ionization chambers meet the response range of 1±0.2;The repeatability of 78 ionization chambers dont exceed 1%,and the response nonlinearity does not exceed 6.5%,which meet the specification requirements.The radiation performance test is carried out for the ionization chamber,and it is found that the measuring range of ionization chamber in 9.0×10^(-2)-1.0×10^(9)μGy/h shall not exceed 1±0.2.The energy response to photons above 164 keV tends to 1.0,and has no response ability below 60 keV.The response curve in range of 60 keV to 164 keV appears“bulge”due to theγPhotoelectric effect of photon and inert gas in ionization chamber.In addition,it does not have the monitoring and warning capability for pulse radiation in nuclear criticality accidents.The response time can give accurate indication in measurement range within 2 s,but response time will be extended to 180-360 s at the junction of segmented voltage.The response change of ionization chamber is less than±0.01 affected by ambient temperature and humidity,showing excellent environmental adaptability.
关 键 词:空气比释动能率 高气压电离室 辐射性能测试 响应
分 类 号:X830[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.49