检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:裴俊强 PEI Junqiang(Taiyuan Heating Group Co.,Ltd.,Taiyuan 030000,China)
机构地区:[1]太原市热力集团有限责任公司,山西太原030000
出 处:《区域供热》2024年第1期46-55,共10页District Heating
摘 要:以太原市供热现状为基础,分析多热源联合供热现状,探讨二次网分布式调峰锅炉与集中供热系统串、并联两种运行方式下的系统性能,建立热平衡方程和调节公式,并对相关运行参数进行求解。计算结果表明,相比串联连接,并联连接能耗更低。研究结果对区域多热源联合供热系统的设计及优化运行具有一定的指导价值。Based on the current situation of heating in Taiyuan,the current situation of multi-heat source combined heating is analyzed,the system performance of secondary network distributed peak-shaving boiler and central heating system in series and parallel operation modes are discussed,the heat balance equation and adjustment formula is established,and the relevant operation parameters are solved.The calculation results show that the energy consumption of parallel connection is relatively lower than that of series connection.The research results of this paper will provide beneficial guidance for the design and optimal operation of regional multi-heat source combined heating system.
分 类 号:TU995[建筑科学—供热、供燃气、通风及空调工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.171