某化工厂区消防泵房设计浅析  

Analysis on the Design of Fire Pump House in a Chemical Plant

在线阅读下载全文

作  者:王艳 刘敏 彭亚宁 曹守凯 Wang Yan;Liu Min;Peng Yaning;Cao Shoukai(Shandong Tianli Technology Engineering Co.,Ltd.,Jinan 250101,China)

机构地区:[1]山东天力科技工程有限公司,山东济南250101

出  处:《山东化工》2024年第2期185-187,190,共4页Shandong Chemical Industry

摘  要:结合实际工程,阐述了化工项目独立建造的电动消防泵、柴油消防泵和生产加压泵合建的泵房平面设计要点。从建筑物定性、是否设置封闭楼梯间或防烟楼梯间、疏散距离、储油量的多少、储油箱的设置、管道的走向等问题进行了探讨。针对规范不明确、争议较大的问题,提出解决方案和看法,管道布置提出不同的优化设计思路。This article combined with the actual project,expounded the main points of the plane design of the pump house which were composed of electric fire pump,diesel fire pump and pressure pump in a chemical plant.It paper probed into the problems such as the nature of buildings,whether to set up enclosed staircases or smoke-proof staircases,evacuation distance,the quantity of oil storage,the setting of oil storage tanks and the trend of pipelines,etc.In view of the problems with unclear standards and controversial problems,we put forward our own solutions and views.Different optimization design ideas were put forward for pipeline layout.

关 键 词:柴油消防泵 火灾危险性 储油量 封闭楼梯间 疏散距离 

分 类 号:TQ082[化学工程]

 