作 者:李俊 范斌斌 曾庆杰 张家瑞 马天 翟小伟 郝乐 肖安山 张贺 王振 LI Jun;FAN Binbin;ZENG Qingjie;ZHANG Jiarui;MA Tian;ZHAI Xiaowei;HAO Le;XIAO Anshan;ZHANG He;WANG Zhen(School of Safety Science and Engineering,Xi′an University of Science and Technology,Xi′an 710054,China;Shaanxi Provincial Key Laboratory of Coal Fire Disaster Prevention,Xi′an 710054,China;State Key Laboratory of Chemical Safety,SINOPEC Research Institute of Safety Engineering Co.,Ltd.,Qingdao 266000,China)
机构地区:[1]西安科技大学安全科学与工程学院,陕西西安710054 [2]陕西省煤火灾害防治重点实验室,陕西西安710054 [3]中石化安全工程研究院有限公司化学品安全全国重点实验室,山东青岛266000
出 处:《光学精密工程》2024年第4期467-477,共11页Optics and Precision Engineering
基 金:国家重点研发计划资助项目(No.2021YFE0105000)。
摘 要:H_(2)S,CH_(4)多组分气体浓度测量技术的研究对石油石化行业的安全生产有重要意义。基于中红外TDLAS技术,选用中心波长为8.309μm的量子级联激光器(Quantum Cascade Laser,QCL)为检测光源,搭建30 m长距离的遥测实验系统,使用WMS波长调制法对H2S,CH4气体的吸收谱线进行连续调谐与扫描,并对高频正弦载波进行了最优深化调制,实现了H2S,CH4多组分气体的同时测量。实验将H2S与5%体积分数的高浓度水汽进行混合测量,分析并验证了该波段的水汽吸收难以对测量造成交叉干扰的优良特性,并利用Savitzky-Golay平滑滤波器提高了检测信号的信噪比。通过遥测实验,分析了15 m,30 m不同遥测距离对检测信号的影响,并利用增加积分时间与计算信噪比的方法,得到了128.75×10^(-9)m的遥测最低限。最后,Allan方差的计算结果表明,当积分时间为183 s,142 s时,系统对H2S,CH4气体的最低检测下限分别为0.593×10^(-9)和1.160×10^(-9)。本文的研究结果为中红外波段H2S,CH4多组分气体的高灵敏度、同时测量提供了一种有效途径,为多组分气体的遥测应用提供了参考。The research of hydrogen sulfide(H_(2)S)and methane(CH_(4))concentration measurement technology is of great significance to petroleum and petrochemical industry.In this paper,a Quantum Cascade Laser(QCL)with a center wavelength of 8.309μm was selected as the detection light source based on Tunable Diode Laser Absorption Spectroscopy(TDLAS)technology.A 30 m long distance sensing sys⁃tem was established by using Wavelength Modulated Spectroscopy(WMS)technology to measure the mixture of H2S and CH4 gases.The experiment mixed H2S with 5%volume fraction of water vapor for measurement,and it showed excellent absorption characteristics in this band,with less cross-interference.Through sensing experiments,the impact of different sensing distances of 15 m and 30 m on the detection signal was analyzed.By increasing integration time and calculating the signal-to-noise ratio,a minimum sensing limit of 128.75×10^(-9)m was achieved.Finally,Allan variance calculations revealed that when in⁃tegration time was 183 s and 142 s,the lowest detection limits for H2S and CH4 were 0.593×10^(-9)and 1.160×10^(-9),respectively.The results provide an effective method for remote measurement of highly sen⁃sitive H2S and CH4 multi-component gases and ensure safe operation in a variety of industrial environ⁃ments.
分 类 号:TN216[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.117.107.97