检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:李沅[1] 王翔宇 马金竹[1] 梁慧媛 LI Yuan;WANG Xiang-yu;MA Jin-zhu;LINAG Hui-yuan(Supervision and Testing Center for Medical Devices of Tianjin,Tianjin 300384)
机构地区:[1]天津市医疗器械质量监督检验中心,天津300384
出 处:《中国医疗器械信息》2024年第5期17-19,99,共4页China Medical Device Information
摘 要:目的:建立血液透析液中乳酸根的含量测定方法。方法:高效液相色谱法。色谱柱:phenomenex Rezex ROA-Organic Acid(300mm×7.8mm,8μm);流动相:0.015mol/L硫酸溶液;检测波长:220nm。结果:在0.18~0.72mg/mL范围内,质量浓度与峰面积呈良好的线性关系(r^(2)=1),平均回收率为100.4%,RSD=0.46%(n=9)。结论:该方法简便,准确,重现性好,可用于血液透析液中乳酸根的含量控制。Objective:To establish a method for the content determination of lactic acid in the haemodialysis.Methods:HPLC analysis was carried out with phenomenex Rezex ROA-Organic Acid(300mm×7.8mm,8μm)and 0.015mol/L sulfuric acid solution as the mobile phase.The detection wavelength was 220nm.Results:There was a good linear relationship between the concentration of lactic acid and the areas in the range of 0.18-0.72mg/mL(r^(2)=1).The average recovery was 100.4%with RSD=0.46%(n=9).Conclusion:The method is simple,accurate and reproducible.It can be used as the quality control for lactic acid in the haemodialysis.
分 类 号:TH776[机械工程—仪器科学与技术]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.223.106.232