作 者:李砂 黄智研 卢钒 孔艳丽 马江雅[1,2] 聂勇[1,2] LI Sha;HUANG Zhiyan;LU Fan;KONG Yanli;MA Jiangya;NIE Yong(School of Civil Engineering and Architecture,Anhui University of Technology;Engneering Research Center of Biofilm Water purification and Utilization technology of Education,Anhui University of Technology,Ma'anshan 243002,China)
机构地区:[1]安徽工业大学建筑工程学院,安徽马鞍山243032 [2]安徽工业大学生物膜法水质净化及利用技术教育部工程研究中心,安徽马鞍山243032
出 处:《水处理技术》2024年第4期111-116,123,共7页Technology of Water Treatment
基 金:城市水资源与水环境国家重点实验室开放基金(ES201917);安徽省科技厅自然科学基金资项目(2008085QE242,2208085Y18);安徽工业大学生物膜法水质净化及利用技术教育部工程研究中心开放课题资助项目(BWPU2020KF08)。
摘 要:针对南方某市微污染水源水(XJ)低温低浊及氨氮问题,采用烧杯实验及中试动态运行实验进行复合助凝剂强化混凝耦合改性沸石过滤处理低温低浊及氨氮效能研究。结果表明,配置的Fe/Si复合助凝剂在絮凝初期投加时明显提高了低温低浊水的出水水质。复合助凝剂的存在起到良好的吸附架桥作用,提高混凝效果。强化混凝对氨氮去除作用有限,不足10%。改性沸石颗粒(MZK)能够利用离子交换和化学吸附作用显著提高氨氮去除效果,去除率达到83.1%。在连续中试动态运行中,出水浊度基本控制在0.6 NTU;在240 h的运行周期内,MZK对氨氮的去除效果明显优于石英砂,氨氮的平均去除率为77.6%,出水处氨氮浓度均小于0.5 mg/L。强化混凝耦合改性沸石过滤为低温低浊及氨氮的水处理提供了理论基础和技术参考,具有较好的应用前景和推广价值。A beaker and a pilot dynamic operation experiments were conducted to study the effectiveness of a low-temperature,low-turbidity,and ammonium treatment using a composite coagulant-enhanced coagulation coupled with modified zeolite filtration for a southern city's micro-polluted raw water source(XJ).The results showed that the effluent quality of low-temperature and low-turbidity water was improved by the Fe/Si composite coagulant at the early stage of flocculation.The presence of the composite coagulant will play a good adsorption bridging effect,thus the coagulation was improved.The effect of enhanced coagulation on ammonium removal was limited to less than 10%.The modified zeolite particles(MZK)were able to use ion exchange and chemisorption,which significantly improved the removal of ammonium following the enhanced coagulation with a removal rate of 83.1%.In continuous pilot dynamic operation,the turbidity of the effluent was basically controlled at 0.6 NTU.During the 240 h operation cycle,the MZK was significantly more effective than quartz sand in removing ammonium with an average removal rate of 77.6%for ammonium,and the effluent ammonium concentration was less than 0.5 mg/L.The enhanced coagulation coupled with modified zeolite filtration provided a theoretical basis and technical reference for water treatment of low-temperature,low-turbidity and ammonium,with good application prospects and promotion value.
关 键 词:低温低浊 氨氮 助凝剂强化混凝 改性沸石过滤 耦合处理
分 类 号:X703.1[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.223.106.232