作 者:Wei Li Xin Pan Dehong Ge Jinji Gao
机构地区:[1]Key Laboratory of Engine Health Monitoring-Control and Networking of Ministry of Education,Beijing University of Chemical Technology,Beijing 100029,China [2]Beijing Key Laboratory of High-End Mechanical Equipment Health Monitoring and Self-Recovery,Beijing University of Chemical Technology,Beijing 100029,China
出 处:《Journal of Bionic Engineering》2024年第1期325-343,共19页仿生工程学报(英文版)
基 金:the financial support through Beijing Natural Science Foundation(Grant No.3212010);National Natural Science Foundation of China(Grant No.51875031).
摘 要:The rotor is the most important component of rotating machinery,and the vibration produced by its mass unbalance has a serious influence on the secure and steady operation of the machine,so an effective online suppression technology is urgently needed.A new hydraulic unbalanced bionic self-recovery system is introduced,imitating the way of manually repairing faulty equipment.To accomplish the effect of actuator mass redistribution,the technology employs pressurized air to drive the quantitative transfer of liquid in the reservoir cavity at opposite positions.It can complete the online adjustment of the equipment's balancing state and suppress the unbalanced vibration of equipment in real time,which gives the equipment the ability to maintain an autonomous health state and improve equipment performance.The composition and working principle of the system are introduced in detail,and the key performance parameters,such as the minimum running speed and the balancing liquid transfer speed,are analyzed theoretically.The fluid-solid coupling model of the actuator was established,and the two-phase flow from inside the hydraulic unbalanced bionic self-recovery actuator was simulated under multiple working conditions and the performance parameters were quantitatively analyzed.A balancing simulation test bed was built,and its effectiveness was verified by performance parameter tests and unbalanced bionic self-recovery experiments.The experimental results show that the mass distribution adjustment of the balancing disk can be achieved using different viscosity balancing liquid,and the response of liquid viscosity 10 cSt is faster than that of liquid viscosity 100 cSt in the process of balancing liquid transfer,and the time is reduced by more than 75%;the system can reduce the simulated rotor amplitude from 18.3μm to 10.6μm online in real time,which provides technical support for the subsequent development of a new generation of bionic intelligent equipment.
关 键 词:Engineering self-recovery-Bionics Simulation analysis Self-recovery regulation
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.149.249.124