检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:韩瑞婷 Han Ruiting(China IPPR International Engineering Co.,Ltd.,Beijing)
机构地区:[1]中国中元国际工程有限公司,北京
出 处:《暖通空调》2024年第4期158-163,共6页Heating Ventilating & Air Conditioning
摘 要:以梅州市某传染病医院通风系统设计为例,探讨了传染病医院“三区两通道”机械送排风系统的设计原则。从空气处理、压力梯度、气流组织、风量平衡等方面介绍了传染病医院平疫结合下的通风系统设计,为类似项目设计提供参考。Taking the design of the ventilation system for an infectious disease hospital in Meizhou as an example,this paper discusses the design principle of the“three zones and two channels”mechanical air supply and exhaust system of the infectious disease hospital.The design of the ventilation system under the combination of peacetime and epidemic periods in this infectious disease hospital is presented from air treatment,pressure gradient,air distribution,and air volume balance,which provides a reference for the design of similar projects.
关 键 词:传染病医院 三区两通道 平疫结合 压力梯度 风量平衡
分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]