作 者:李锋 莫俊峰 程天飞 翁彪 石红星 王利蓉 张佼 LI Feng;Mo Junfeng;CHENG Tianfei;WENG Biao;SHI Hongxing;WANG Lirong;ZHANG Jiao(Department Urological Surgery,Liangping District People’s Hospital,Chongqing 405200,China)
机构地区:[1]重庆市梁平区人民医院泌尿外科,重庆405200
出 处:《重庆医学》2024年第7期1050-1053,共4页Chongqing medicine
基 金:创伤、烧伤与复合伤国家重点实验室开放课题项目(SKLKF202122)。
摘 要:目的比较智能控压系统输尿管软镜钬激光碎石与经皮肾镜钬激光碎石治疗复杂性肾结石的治疗效果。方法选取2022年3月至2023年9月该院收治的复杂性肾结石患者70例,按治疗方法不同分为两组,每组35例。观察组采取智能控压系统输尿管软镜钬激光碎石治疗,对照组采取经皮肾镜钬激光碎石治疗。比较两组患者相关临床指标水平、治疗前后炎症指标水平、结石清除率及并发症发生率。结果观察组患者相关临床指标水平,包括术中出血量、手术时间、术后血红蛋白下降值、住院时间、术后下床活动时间较对照组减少或提前,差异有统计学意义(P<0.05);观察组结石清除率高于对照组(P<0.05),并发症发生率低于对照组(P<0.05),两组患者输血、再次手术栓塞止血发生率比较差异无统计学意义(P>0.05)。结论智能控压系统输尿管软镜钬激光碎石治疗复杂性肾结石可减少术后并发症,缩短术后康复时间,提高患者结石清除率,减少相关并发症发生,可临床上推广。Objective To compare the effect between intelligent pressure control system flexible ureteroscopy and percutaneous nephroscopic holmium laser lithotripsy in the treatment of complex kidney stones.Methods Seventy patients with complex kidney stones admitted and treated in this hospital from March 2022 to September 2023 were selected and divided into 2 groups according to different treatment methods,35 cases in each group.The observation group was treated by ureteral soft lens holmium laser lithotripsy with intelligent pressure control system.The control group was treated with percutaneous nephroscopic holmium laser lithotripsy.The level of related clinical indicators,inflammatory indicators before and after treatment,stone clearance rate and complications occurrence rate were compared between the two groups.Results The levels of related clinical indicators in the observation group,including intraoperative blood loss volume,operation time,postoperative hemoglobin decline value,hospital stay duration,and postoperative bed activity time,were lower than those in the control group,and the differences were statistically significant(P<0.05).The stone clearance rate in the observation group was higher than that in the control group,and the complications occurrence rate was lower than that in the control group(P<0.05).There was no statistical difference in blood transfusion and occurrence rate of re-operation embolization hemostasis between the two groups(P>0.05).Conclusion The intelligent pressure control system ureteral flexible holmium laser lithotripsy in the treatment of complex kidney stones could reduce postoperative complications,shorten postoperative rehabilitation time,increase the stone clearance rate,control the related complications of the patients,which can be promoted and applied in clinic.
关 键 词:智能控压系统输尿管软镜 经皮肾镜 复杂性肾结石 结石清除率
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.16.44.204