检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:Lingpeng Zhan Yanyi Huang Guanbo Wang
机构地区:[1]Institute for Cell Analysis,Shenzhen Bay Laboratory,Shenzhen 518132,China [2]Biomedical Pioneering Innovation Center,Peking University,Beijing 100871,China
出 处:《Chinese Chemical Letters》2024年第3期214-220,共7页中国化学快报(英文版)
基 金:supported by grants from the National Natural Science Foundation of China(No.21974069);Open Fund Programs of Shenzhen Bay Laboratory(No.SZBL2020090501001)。
摘 要:Matrix-assisted laser desorption/ionization(MALDI)mass spectrometry(MS)plays an indispensable role in analyzing protein covalent structures.The reliable identification of amino acid residues and modifications relies on the mass accuracy,which is highly dependent on calibration.However,the accuracy provided by the currently available calibrants still needs further improvement in terms of compatibility with multiple tandem MS modes or ion polarity modes,calibratable range,and minimizing suppression of and interference with analyte signals.Here aiming at developing a versatile calibrant to solve these problem,we designed a synthetic peptide format of calibrant R_x(GDP_n)_m(referred to as“Gly-Asp-Pro,GDP”)according to the chemical natures of amino acids and polypeptide fragmentation rules in tandem MS.With four types of amino acid residues selected and arranged through rational designs,a GDP peptide produces highly regulated fragments that give rise to evenly spaced signals in each tandem MS mode and is compatible with both positive and negative ion modes.In internal calibration,its regulated fragmentation pattern minimizes interference with analyte signals,and using a single peptide as the input minimizes suppression of the analyte signals.As demonstrated by analyses of proteins including monoclonal antibody and Aβ-42,these features allowed significant increase of the mass accuracy and precision,which improved sequence coverage and sequence resolution in sequence analyses(including de novo sequencing).This rational design strategy may also inspire further development of synthetic calibrants that benefit structural analysis of biomolecules.
关 键 词:Biomolecule design Synthetic peptide Protein sequencing Covalent structure De novo sequencing Mass spectrometry Gas-phase fragmentation
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229