检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马莹 杨永 谭铃 巢静波[5] 樊丽妃 贺岩涛 陈艳[5] 杨婧[1] MA Ying;YANG Yong;TAN Ling;CHAO Jingbo;FAN Lifei;HE Yantao;CHEN Yan;YANG Jing(State Environmental Protection Key Laboratory of Quality Control in Environmental Monitoring,China National Environmental Monitoring Center,Beijing 100012,China;Xinjiang Ecological Environment Monitoring Center,Urumqi 830011,China;State Environmental Protection Key Laboratory of Environmental Pollutant Metrology and Reference Materials,Institute for Environmental Reference Materials,Ministry of Ecology and Environmental,Beijing 100029,China;Chongqing Ecological and Environmental Monitoring Center,Chongqing 401147,China;National Institute of Metrology,Beijing 100029,China;Guangdong Ecological Environment Monitoring Center,Guangzhou 510308,China)
机构地区:[1]中国环境监测总站,国家环境保护环境监测质量控制重点实验室,北京100012 [2]新疆维吾尔自治区生态环境监测总站,新疆乌鲁木齐830011 [3]生态环境部环境发展中心环境标准样品研究所,国家环境保护污染物计量和标准样品研究重点实验室,北京100029 [4]重庆市生态环境监测中心,重庆401147 [5]中国计量科学研究院,北京100029 [6]广东省生态环境监测中心,广东广州510308
出 处:《中国环境监测》2024年第2期198-204,共7页Environmental Monitoring in China
摘 要:针对高锰酸盐指数(COD_(Mn))和氨氮(NH_(3)-N)标准溶液(以下简称液标)制造商、浓度水平和使用情况进行调研,根据调研结果选择常用的7个品牌COD_(Mn)液标和9个常用NH_(3)-N液标品牌开展量值比对和质量评价研究,匿名采购129支液标经盲样编码后采用《地表水环境质量标准》(GB 3838—2002)推荐标准进行分析测定,计算和评定测定结果的不确定度,以En法进行量值比对评价。研究表明,NH_(3)-N液标量值均满意,COD_(Mn)测试中的加盖操作会使测定结果偏高,按照证书要求操作时COD_(Mn)液标量值合格,未按照液标证书中要求进行液标样品前处理测定会造成测定结果的偏离,影响评价结果。建议监测人员合理选用和规范使用环境用液标,加强环境用液标的选购和管理,确保检测过程得到有效控制。This study investigated the manufacturers,concentration levels and usage of the reference materials permanganate index(COD_(Mn))and ammonia nitrogen(NH_(3)-N)for environmental monitoring.According to the survey results,7 commonly used brands of COD_(Mn)liquid standard and 9 commonly used brands of NH_(3)-N liquid standard were selected to carry out the property value comparison and quality evaluation research.129 liquid standards were anonymously purchased and measured by the recommended standard of GB 3838-2002 after recoded.The uncertainty of determination results was calculated and evaluated,and the En value method was used for comparison and evaluation.The research showed that the property value of NH_(3)-N standard were all satisfied,the capping operation in COD_(Mn)test would cause the measurement results to be higher.If the pre-treatment test unfollowed the requirement of the standard label certificate,it would cause the deviation of the test result and finally affect the evaluation result.It was suggested that the monitoring personnel should rationally select and standardize the use of environmental liquid standards,strengthen the selection and management of environmental liquid standards to ensure the effective control of the testing process.
关 键 词:环境监测 标准物质/标准样品 高锰酸盐指数 氨氮 质量评价 量值比对
分 类 号:X830.5[环境科学与工程—环境工程]