防雷插座电压保护水平试验方法解析  

Analysis of Test Methods for Voltage Protection Level of Surge Protecting Sockets

在线阅读下载全文

作  者:马壮[1] 

机构地区:[1]上海市质量监督检验技术研究院,上海201114

出  处:《日用电器》2024年第3期115-118,共4页ELECTRICAL APPLIANCES

基  金:上海市质量监督检验技术研究院科研项目,项目编号:KY-2021-3-DJ。

摘  要:本文解析了防雷插座电压保护水平的试验方法。首先,介绍了用于测试防雷插座电压保护水平两个常用标准IEC61643-11和UL1449的不同要求。其次,基于IEC61643-11和UL1449标准对防雷插座电压保护水平进行试验及分析。最后,总结了两种测试方法的优缺点,并指出在实际应用中应根据具体需求选择适合的测试方法,以确保防雷插座的性能和质量。This article analyzes the testing methods for the voltage protection level of surge protectors.Firstly,it introduces the different requirements of IEC 61643-11 and UL 1449,which are two commonly used standards for testing the voltage protection level of surge protectors.Secondly,it discusses the testing and analysis of the voltage protection level of surge protectors based on the IEC 61643-11 and UL 1449 standards.Finally,it summarizes the advantages and disadvantages of the two testing methods and points out that the appropriate testing method should be chosen according to specific requirements in order to ensure the performance and quality of surge protectors.

关 键 词:防雷插座 电压保护水平 试验方法分析 