检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘晓飞 杨力源 李昂 LIU Xiaofei;YANG Liyuan;LI Ang(UHV Branch of State Grid Hebei Electric Power Co.,Ltd.,Shijiazhuang,Hebei 050070,China)
机构地区:[1]国网河北省电力有限公司超高压分公司,河北石家庄050070
出 处:《山西电力》2024年第2期15-18,共4页Shanxi Electric Power
摘 要:准确测量设备回路电阻,可以有效判断设备导电回路是否存在接触面氧化、接触不良缺陷,避免因回路电阻超标导致设备发热。综述了设备回路电阻测试方法和测试误区,分析了测试接线对测量结果的影响,提出了采用外扩导流法准确测量GIS设备回路电阻的方法,并结合现场测试发现的一起地刀合闸不到位故障,验证了测试方法的准确性,为测量设备回路电阻提供了指导。Accurate measurement of the circuit resistance of the equipment can effectively help to determine whether the conductive circuit of the equipment has the defects of oxidation of the contact surface or poor contact,so as to avoid the equipment overheating caused by the excessive circuit resistance.The test methods and errors of equipment circuit resistance are summarized and the influence of test wiring on the measurement results is analyzed.Based on these,a method to accurately measure the circuit resistance of GIS equipment by using the external expansion diversion is proposed,and the accuracy of the test is verified based on the failure of the ground cutter closing in place found in the field test,which provides guidance for measuring the circuit resistance of equipment.
关 键 词:气体绝缘金属封闭开关设备 回路电阻 接触不良 老化